The detection of axillary lymph node metastases from breast cancer by radiolabelled monoclonal antibodies: a prospective study
Open Access
- 1 February 1989
- journal article
- research article
- Published by Springer Nature in British Journal of Cancer
- Vol. 59 (2) , 296-302
- https://doi.org/10.1038/bjc.1989.61
Abstract
In a prospective study to assess the accuracy of monoclonal immunoscintigraphy for the detection of axillary lymph node metastases in breast cancer, two murine monoclonal antibodies that react with human breast cancer (3E1.2 and RCC-1) were labelled with 131iodine, and the radiolabelled antibody was injected subcutaneously into the interdigital spaces of both hands of 40 patients, 36 of whom had breast cancer and the remaining four of whom had fibroadenoma (the normal, contralateral axilla was used as a control). Of the patients with breast cancer, the findings from the scintigraphy images were correlated with histopathology or cytology of the axillary lymph nodes; images were regarded as positive and hence indicative of lymph node metastases if the amount of background-subtracted radioactive count in axilla on the side of breast cancer exceeded the contralateral normal side by a ratio greater than or equal to 1.5:1.0 as assessed by computer analysis. Using this method, immunoscintigraphy had an overall sensitivity of 33% (23% with 131I-3E1.2 and 50% with 131I-RCC-1) for the detection of lymph node metastases and a specificity of 63% (67% with 131I-3E1.2 and 60% with 131I-RCC-1) with problems of non-specific uptake by presumably normal lymph nodes. The results of immunoscintigraphy obtained with 131I-RCC-1 (IgG) were superior to 131I-3E1.2 (IgM) although the accuracy of immunoscintigraphy using 131I-RCC-1 (56%) was not much better than preoperative clinical assessment (50%). However, there were cases when immunoscintigraphy using radiolabelled antibody (IgM or IgG) detected axillary lymph node metastases not suspected by clinical examination. Thus it appears that while immunoscintigraphy may be a useful adjunct to preoperative clinical assessment and is simple and safe, a major improvement in its accuracy is needed before it can replace axillary dissection and histological examination in the accurate staging of axilla in breast cancer.Keywords
This publication has 26 references indexed in Scilit:
- Lack of efficacy of lymphoscintigraphy in detecting axillary lymph node metastases from breast cancerEuropean Journal of Cancer and Clinical Oncology, 1987
- IMMUNOSCINTIGRAPHY FOR DETECTION OF LYMPH NODE METASTASES FROM BREAST CANCERThe Lancet, 1984
- IMAGING OF T-CELL LYMPHOMA BY RADIOLABELLED MONOCLONAL ANTIBODYThe Lancet, 1984
- The localization of human breast carcinomas by radiolabelled monoclonal antibodiesBritish Journal of Surgery, 1984
- The localization of an anti-tumour monoclonal antibody (791T/36) in gastrointestinal tumoursBritish Journal of Surgery, 1984
- Particle sizing and biokinetics of interstitiallymphoscintigraphic agentsSeminars in Nuclear Medicine, 1983
- A new solid-state reagent to iodinate proteinsAnalytical Biochemistry, 1982
- A sensitive rosetting method for detecting subpopulations of lymphocytes which react with alloantiseraJournal of Immunological Methods, 1978
- STUDIES ON THE PERMEABILITY OF LYMPHATIC CAPILLARIESThe Journal of cell biology, 1971
- THE PREPARATION OF 131I-LABELLED HUMAN GROWTH HORMONE OF HIGH SPECIFIC RADIOACTIVITYBiochemical Journal, 1963