Abstract
Low tidal volume (Vt) ventilation is protective against ventilator-induced lung injury but can promote development of atelectasis. Periodic deep inflation (DI) can open the lung, but if delivered too frequently may cause damage via repeated overdistention. We therefore examined the effects of varying DI frequency on lung mechanics, gas exchange, and biomarkers of injury in mice. C57BL/6 males were mechanically ventilated with positive end-expiratory pressure (PEEP) of 2 cmH2O for 2 h. One high Vt group received a DI with each breath (HV). Low Vt groups received 2 DIs after each hour of ventilation (LV) or 2 DIs every minute (LVDI). Control groups included a nonventilated surgical sham and a group receiving high Vt with zero PEEP (HVZP). Respiratory impedance was measured every 4 min, from which tissue elastance ( H) and damping ( G) were derived. G and H rose progressively during LV and HVZP, but returned to baseline after hourly DI during LV. During LVDI and HV, G and H remained low and gas exchange was superior to that of LV. Bronchoalveolar lavage fluid protein was elevated in HV and HVZP but was not different between LV and LVDI. Lung tissue IL-6 and IL-1β levels were elevated in HVZP and lower in LVDI compared with LV. We conclude that frequent DI can safely improve gas exchange and lung mechanics and may confer protection from biotrauma. Differences between LVDI and HV suggest that an optimal frequency range of DI exists, within which the benefits of maintaining an open lung outweigh injury incurred from overdistention.Keywords
This publication has 42 references indexed in Scilit:
- Pulmonary impedance and alveolar instability during injurious ventilation in ratsJournal of Applied Physiology, 2005
- Effects of mechanical ventilation at low lung volume on respiratory mechanics and nitric oxide exhalation in normal rabbitsJournal of Applied Physiology, 2005
- Oxygen limitation of thermal tolerance in cod,Gadus morhuaL., studied by magnetic resonance imaging and on-line venous oxygen monitoringAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 2004
- Tissue heterogeneity in the mouse lung: effects of elastase treatmentJournal of Applied Physiology, 2004
- Intracellular glutathione in stretch-induced cytokine release from alveolar type-2 like cellsRespirology, 2004
- Dynamic mechanical consequences of deep inflation in mice depend on type and degree of lung injuryJournal of Applied Physiology, 2004
- Recruitment maneuver: Does it promote bacterial translocation?*Critical Care Medicine, 2002
- Exacerbation by granulocyte colony-stimulating factor of prior acute lung injury: Implication of neutrophilsCritical Care Medicine, 2002
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeNew England Journal of Medicine, 2000
- Open up the lung and keep the lung openIntensive Care Medicine, 1992