Trapping and removal of oxygen in tokamaks
- 1 December 1977
- journal article
- Published by IOP Publishing in Nuclear Fusion
- Vol. 17 (6) , 1143-1151
- https://doi.org/10.1088/0029-5515/17/6/004
Abstract
Various discharge cleaning techniques have been studied in Microtor. It was found that high temperature discharges are not only ineffective in reducing the oxygen on the wall, and hence in the plasma, but may even induce trapping. Oxygen can be removed from the wall by a low-temperature, partially ionized hydrogen plasma by conversion to water vapour. The amount of loosely bound oxygen on the surface is thus reduced below 1% of a monolayer. The residual amount of the oxygen in the plasma is near 1010 atom cm−3, and represents a significant improvement over previous tokamak results.Keywords
This publication has 6 references indexed in Scilit:
- Aluminium limiter experiment in ST tokamakNuclear Fusion, 1976
- Radiation limits to tokamak operationNuclear Fusion, 1976
- Line radiation in the visible and in the ultraviolet in TFR tokamak plasmasNuclear Fusion, 1975
- Control of re-cycling and impurities in the ATC tokamak by means of gettered surfacesNuclear Fusion, 1975
- Radiation power of a plasma as a function of the discharge parameters in the Tokamak-3 deviceNuclear Fusion, 1972
- Gas Discharge Cleaning of Vacuum SurfacesJournal of Vacuum Science and Technology, 1970