Spherical lesion phantoms for testing the performance of elastography systems
- 6 December 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (24) , 5983-5995
- https://doi.org/10.1088/0031-9155/50/24/015
Abstract
A set of three cubic one-litre phantoms containing spherical simulated lesions was produced for use in comparing lesion detection performance of different elastography systems. The materials employed are known to be stable in heterogeneous configurations regarding geometry and elastic contrast identical with (storage modulus of lesion material) / (storage modulus of background material), and regarding ultrasound and NMR properties. The materials mimic soft tissues in terms of elastic, ultrasound and NMR properties. Each phantom has only one value of elastic contrast (3.3, 4.6 or 5.5) and contains arrays of 1.6 mm, 2 mm, 3 mm and 4 mm diameter spherical simulated lesions. All the spheres of a given diameter are arranged in a regular array with coplanar centres. Elastograms of an array made with ultrasound allow determination of the depth range over which lesions of that diameter and elastic contrast can be detected. Two phantoms are made from agar-plus-gelatin-based materials, and one is made from oil-in-gelatin dispersions. The methods for producing the phantoms are described in detail. Lesion detection performances for two ultrasound systems, both operating at about 7.5 MHz and focused at about 5 cm, were quantified with distinctions between the two systems demonstrated. Neither system was capable of detecting any of the 1.6 mm lesions. Phantoms such as these should be useful in research labs that are refining hardware and/or software for elastography.Keywords
This publication has 15 references indexed in Scilit:
- Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gelsUltrasound in Medicine & Biology, 2006
- Tissue-mimicking agar/gelatin materials for use in heterogeneous elastography phantomsPhysics in Medicine & Biology, 2005
- Viscoelastic shear properties of in vivo breast lesions measured by MR elastographyMagnetic Resonance Imaging, 2005
- Tissue-Mimicking Oil-in-Gelatin Dispersions for Use in Heterogeneous Elastography PhantomsUltrasonic Imaging, 2003
- A Modified Block Matching Method for Real-Time Freehand Strain ImagingUltrasonic Imaging, 2002
- Improved method for determining resolution zones in ultrasound phantoms with spherical simulated lesionsUltrasound in Medicine & Biology, 2001
- Anthropomorphic 1H MRS head phantomMedical Physics, 1998
- Error analysis in acoustic elastography. I. Displacement estimationThe Journal of the Acoustical Society of America, 1997
- An overview on the time delay estimate in active and passive systems for target localizationIEEE Transactions on Acoustics, Speech, and Signal Processing, 1981
- The generalized correlation method for estimation of time delayIEEE Transactions on Acoustics, Speech, and Signal Processing, 1976