Investigation of the profiling depth in matrix‐assisted laser desorption/ionization imaging mass spectrometry
- 13 December 2005
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 20 (2) , 284-290
- https://doi.org/10.1002/rcm.2259
Abstract
Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry is generally considered to be a surface analysis technique. In this report, the profiling depth of imaging mass spectrometry was examined. MALDI matrix solution was found to be able to gain access to the tissue interior and extract analyte molecules to the tissue surface. As a consequence, prazosin, a small molecule pharmaceutical compound, located as deep as 40 µm away from the surface was readily detected after matrix application. Likewise, cytochrome c, a 12 kDa protein, was also detectable from the tissue interior. Moreover, for prazosin, not only the extent of matrix effect, but also the extraction efficiency of the matrix solvent appeared to be dependent on the type of tissue. These results indicated that experimental conditions that decrease the matrix solvent evaporation during matrix application may increase analyte extraction efficiency and hence sensitivity of the analysis. Furthermore, thin sections should be used to avoid differential extraction efficiency of matrix solvent in different tissues for whole-body analysis. Copyright © 2005 John Wiley & Sons, Ltd.Keywords
This publication has 19 references indexed in Scilit:
- Integrating Histology and Imaging Mass SpectrometryAnalytical Chemistry, 2004
- Direct analysis of drug candidates in tissue by matrix‐assisted laser desorption/ionization mass spectrometryJournal of Mass Spectrometry, 2003
- Quantitative analysis of small pharmaceutical drugs using a high repetition rate laser matrix-assisted laser/desorption ionization sourceRapid Communications in Mass Spectrometry, 2003
- Direct tissue analysis using matrix‐assisted laser desorption/ionization mass spectrometry: practical aspects of sample preparationJournal of Mass Spectrometry, 2003
- Post‐column infusion study of the ‘dosing vehicle effect’ in the liquid chromatography/tandem mass spectrometric analysis of discovery pharmacokinetic samplesRapid Communications in Mass Spectrometry, 2003
- An introduction to quadrupole–time‐of‐flight mass spectrometryJournal of Mass Spectrometry, 2001
- Organic film thickness effect in secondary ion mass spectrometry and plasma desorption mass spectrometryInternational Journal of Mass Spectrometry and Ion Processes, 1992
- A simple method for the quantitation of 14C-whole-body autoradiogramsApplied Radiation and Isotopes, 1987
- INFINITE THICKNESS IN AUTORADIOGRAPHS OF CARBON-14Journal of Microscopy, 1987
- Clinical Pharmacokinetics of Prazosin - 1985Clinical Pharmacokinetics, 1985