Combined Cycle Plants With Frame 9F Gas Turbines

Abstract
The new 200 MW class MS 9001F gas turbines allow combined cycle plants to reach even higher output levels and greater efficiency ratings. Size factor and higher firing temperatures, with a three-pressure level steam reheat cycle, offer plant efficiencies in excess of 53 percent. Heat recovery steam generators have been designed to accommodate catalytic reduction elements limiting flue gas NOx emissions to as low as 10 ppm VD (15 percent O2). A range of steam turbine models covers the different possible configurations. Various arrangements based on the 350 or 650 MW power generation modules can be optimally configured to the requirements of each site.

This publication has 0 references indexed in Scilit: