Dried Blood Spots versus Sera for Detection of Rubella Virus-Specific Immunoglobulin M (IgM) and IgG in Samples Collected during a Rubella Outbreak in Peru

Abstract
Most persons with rubella virus-specific immunoglobulin M (IgM)- or IgG-positive sera tested positive (98% [n = 178] and 99% [n = 221], respectively) using paired filter paper dried blood spot (DBS) samples, provided that DBS indeterminate results were called positive. For persons with IgM- or IgG-negative sera, 97% and 98%, respectively, were negative using DBS.