The acoustic emission technique in orthopaedics - a review
- 1 January 2005
- journal article
- review article
- Published by SAGE Publications in The Journal of Strain Analysis for Engineering Design
- Vol. 40 (1) , 59-79
- https://doi.org/10.1243/030932405x7638
Abstract
Traditionally, orthopaedic research has focused upon the assessment of individual components in an implanted construct. A great deal of research has investigated the durability of the metallic stem, even though this is the most robust component in the implanted system. Standards have been developed for the structural assessment of the implant and even the bone cement which holds the implant in place in the bone. However, the construct as a whole, and its short- and long-term structural integrity, are rarely assessed, and few methods have been established to monitor and predict the mechanisms leading to failure. These are necessary to ensure that any new implants entering the market will perform satisfactorily and prevent premature revision surgery. The acoustic emission (AE) technique offers the capability of monitoring structural degradation passively and in real time, and can distinguish failure mechanisms and their location through the analysis of AE parameters. In the present paper, the use of acoustic emission in orthopaedics, in particular for the evaluation of hip replacement constructs, is reviewed. Following this, three case studies undertaken at the University of Southampton are presented, in which acoustic emission on-line monitoring has been used to evaluate the performance of simulated artificial hip replacement constructs and their constituents during static and fatigue testing. In Case Study 1, the fatigue behaviour of bone cement is characterized; in Case Study 2, the residual stresses induced in the construct as a result of bone cement cure are investigated; in Case Study 3, the mechanisms leading to failure of a carbon fibre reinforced plastic hip stem during fatigue testing are characterized.Keywords
This publication has 73 references indexed in Scilit:
- Effects of humidity on environmental stress cracking behavior in poly(methyl methacrylate)Journal of Polymer Science Part B: Polymer Physics, 2001
- Reply to Dr. Akkus's CommentsJournal of Biomedical Materials Research, 2001
- Material fatigue behavior characterization using the wavelet-based AE technique – a case study of acrylic bone cementEngineering Fracture Mechanics, 2001
- Schallemissionsanalyse an menschlichen Knochen im Rahmen der klinischen Diagnostik - Acoustic Emission Analysis as a Diagnostic Tool for the Examination of Human BonesBiomedizinische Technik/Biomedical Engineering, 1998
- The role of aspiration and contrast-enhanced arthrography in evaluating the uncemented hip arthroplasty.American Journal of Roentgenology, 1997
- In vitro measured strains in the loaded femur: Quantification of experimental errorThe Journal of Strain Analysis for Engineering Design, 1997
- In vitro evaluation of bonding of the cement-metal interface of a total hip femoral component using ultrasoundJournal of Orthopaedic Research, 1995
- Acoustic Emission and Nondestructive Evaluation of Biomaterials and TissuesPublished by Begell House ,1995
- A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip componentsJournal of Biomechanics, 1991
- Transient and Residual Stresses and Displacements in Self-Curing Bone Cement—Part I: Characterization of Relevant Volumetric Behavior of Bone CementJournal of Biomechanical Engineering, 1982