Reliability of the American Medical Association Guides' Model for Measuring Spinal Range of Motion
- 1 February 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 24 (3) , 262-268
- https://doi.org/10.1097/00007632-199902010-00013
Abstract
Study Design. Repeated measures design for intra-and interrater reliability. Objectives. To determine the intra- and interrater reliability of the lumbar spine range of motion measured with a dual inclinometer, and the thoracolumbar spine range of motion measured with a long-arm goniometer, as recommended in the American Medical Association Guides. Summary of Background Data. The American Medical Association Guides (2nd and 4th editions) recommend using measurements of thoracolumbar and lumbar range of movement, respectively, to estimate the percentage of permanent impairment in patients with chronic low back pain. However, the reliability of this method of estimating impairment has not been determined. Methods. In all, 34 subjects participated in the study, 21 women with a mean age of 40.1 years (SD, ± 11.1) and 13 men with a mean age of 47.7 years (SD, ± 12.1). Measures of thoracolumbar flexion, extension, lateral flexion, and rotation were obtained with a long-arm goniometer. Lumbar flexion, extension, and lateral flexion were measured with a dual inclinometer. Measurements were taken by two examiners on one occasion and by one examiner on two occasions approximately 1 week apart. Results. The results showed poor intra- and interrater reliability for all measurements taken with both instruments. Measurement error expressed in degrees showed that measurements taken by different raters exhibited systematic as well as random differences. As a result, subjects measured by two different examiners on the same day, with either instrument, could give impairment ratings ranging between 0% and 18% of the whole person (excluding rotation), in which percentage impairment is calculated using the average range of motion and the average systematic and random error in degrees for the group for each movement (flexion, extension, and lateral flexion). Conclusions. The poor reliability of the American Medical Association Guides' spinal range of motion model can result in marked variation in the percentage of whole-body impairment. These findings have implications for compensation bodies in Australia and other countries that use the American Medical Association Guides' procedure to estimate impairment in chronic low back pain patients.Keywords
This publication has 16 references indexed in Scilit:
- Variance in the Measurement of Sagittal Lumbar Spine Range of Motion Among Examiners, Subjects, and InstrumentsSpine, 1995
- Analysis of Spine Motion Variability Using a Computerized Goniometer Compared to Physical Examination A Prospective Clinical StudySpine, 1994
- CommentaryPTJ: Physical Therapy & Rehabilitation Journal, 1993
- ESTIMATION OF NORMAL LUMBAR FLEXION WITH SURFACE INCLINOMETRYAmerican Journal of Physical Medicine & Rehabilitation, 1992
- Reliability and Validity of Clinical Measurement of the Lumbar Spine in Patients with Chronic Low Back PainPublished by Elsevier ,1991
- Repeatability of Four Clinical Methods for Assessment of Lumbar Spinal MotionSpine, 1988
- Reliability and Validity of Four Instruments for Measuring Lumbar Spine and Pelvic PositionsPTJ: Physical Therapy & Rehabilitation Journal, 1986
- Quantification of Lumbar FunctionSpine, 1986
- CORRELATION BETWEEN RADIOGRAPHIC AND CLINICAL MEASUREMENT OF LUMBAR SPINE MOVEMENTRheumatology, 1983
- MEASUREMENT OF SPINAL MOBILITY: ACOMPARISON OF THREE METHODSRheumatology, 1975