Functional definition and characterization of acute traumatic coagulopathy
Top Cited Papers
- 1 December 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 39 (12) , 2652-2658
- https://doi.org/10.1097/ccm.0b013e3182281af5
Abstract
Objective: To identify an appropriate diagnostic tool for the early diagnosis of acute traumatic coagulopathy and validate this modality through prediction of transfusion requirements in trauma hemorrhage. Design: Prospective observational cohort study. Setting: Level 1 trauma center. Patients: Adult trauma patients who met the local criteria for full trauma team activation. Exclusion criteria included emergency department arrival >2 hrs after injury, >2000 mL of intravenous fluid before emergency department arrival, or transfer from another hospital. Interventions: None. Measurements: Blood was collected on arrival in the emergency department and analyzed with laboratory prothrombin time, point-of-care prothrombin time, and rotational thromboelastometry. Prothrombin time ratio was calculated and acute traumatic coagulopathy defined as laboratory prothrombin time ratio >1.2. Transfusion requirements were recorded for the first 12 hrs following admission. Main Results: Three hundred patients were included in the study. Laboratory prothrombin time results were available at a median of 78 (62–103) mins. Point-of-care prothrombin time ratio had reduced agreement with laboratory prothrombin time ratio in patients with acute traumatic coagulopathy, with 29% false-negative results. In acute traumatic coagulopathy, the rotational thromboelastometry clot amplitude at 5 mins was diminished by 42%, and this persisted throughout clot maturation. Rotational thromboelastometry clotting time was not significantly prolonged. Clot amplitude at a 5-min threshold of ≤35 mm had a detection rate of 77% for acute traumatic coagulopathy with a false-positive rate of 13%. Patients with clot amplitude at 5 mins ≤35 mm were more likely to receive red cell (46% vs. 17%, p < .001) and plasma (37% vs. 11%, p < .001) transfusions. The clot amplitude at 5 mins could identify patients who would require massive transfusion (detection rate of 71%, vs. 43% for prothrombin time ratio >1.2, p < .001). Conclusions: In trauma hemorrhage, prothrombin time ratio is not rapidly available from the laboratory and point-of-care devices can be inaccurate. Acute traumatic coagulopathy is functionally characterized by a reduction in clot strength. With a threshold of clot amplitude at 5 mins of ≤35 mm, rotational thromboelastometry can identify acute traumatic coagulopathy at 5 mins and predict the need for massive transfusion.Keywords
This publication has 40 references indexed in Scilit:
- Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM®)-guided administration of fibrinogen concentrate and prothrombin complex concentrateCritical Care, 2010
- Effect of Haemostatic Control Resuscitation on mortality in massively bleeding patients: a before and after studyVox Sanguinis, 2009
- Point-of-care versus central laboratory coagulation testing during haemorrhagic surgeryThrombosis and Haemostasis, 2009
- Increased Plasma and Platelet to Red Blood Cell Ratios Improves Outcome in 466 Massively Transfused Civilian Trauma PatientsAnnals of Surgery, 2008
- Acute Traumatic Coagulopathy: Initiated by HypoperfusionAnnals of Surgery, 2007
- Patterns of Errors Contributing to Trauma MortalityAnnals of Surgery, 2006
- Early Predictors of Transfusion and Mortality After Injury: A Review of the Data-Based LiteratureJournal of Trauma: Injury, Infection & Critical Care, 2006
- Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac SurgeryAnesthesia & Analgesia, 1999
- Thromboelastography-Guided Transfusion Algorithm Reduces Transfusions in Complex Cardiac SurgeryAnesthesia & Analgesia, 1999
- Hemostasis in Massively Transfused Trauma PatientsAnnals of Surgery, 1979