Skin to skin care:heat balance.
Open Access
- 1 September 1996
- journal article
- research article
- Published by BMJ in Archives of Disease in Childhood: Fetal & Neonatal
- Vol. 75 (2) , F130-F132
- https://doi.org/10.1136/fn.75.2.f130
Abstract
Skin to skin care has been practised in primitive and high technology cultures for body temperature preservation in neonates. Regional skin temperature and heat flow was measured in moderately hypothermic term neonates to quantitate the heat transfer occurring during one hour of skin to skin care. Nine healthy newborns with a mean rectal temperature of 36.3 degrees C were placed skin to skin on their mothers' chests. The mean (SD) rectal temperature increased by 0.7 (0.4) degrees C to 37.0 degrees C. The heat loss was high (70 Wm-2) from the unprotected skin of the head to the surrounding air. Minute heat losses occurred from covered areas; and heat was initially gained from areas in contact with the mother's skin. The total dry heat loss during skin to skin care corresponded to heat loss during incubator care at 32-32.5 degrees C. The reduced heat loss, and to a minor extent, the initial heat flux from the mothers allowed heat to be conserved, leading to rewarming.Keywords
This publication has 23 references indexed in Scilit:
- TRANSEPIDERMAL WATER LOSS IN NEWBORN INFANTSActa Paediatrica, 2008
- Regional skin temperature, heat flow and conductance in preterm neonates nursed in low and in neutral environmental temperatureActa Paediatrica, 1996
- Measurement of skin temperature and heat flow from skin in term newborn babiesActa Paediatrica, 1995
- Evaluation of methods for measurement of regional skin temperature and heat flow in neonatesActa Paediatrica, 1995
- Providing warmth for preterm babies by a heated, water filled mattress.Archives of Disease in Childhood, 1989
- Skin to skin contact for very low birthweight infants and their mothers.Archives of Disease in Childhood, 1988
- MYTH OF THE MARSUPIAL MOTHER: HOME CARE OF VERY LOW BIRTH WEIGHT BABIES IN BOGOTA, COLOMBIAThe Lancet, 1985
- THE OPTIMUM DIAMETER FOR A GLOBE THERMOMETER FOR USE INDOORS*Annals of Occupational Hygiene, 1977
- Study by Direct Calorimetry of Thermal Balance on the First Day of LifeEuropean Journal of Clinical Investigation, 1972
- Small globe thermometersJournal of Physics E: Scientific Instruments, 1968