Effect of Particle Size on Quartz-Induced Hemolysis and on Lung Inflammation and Fibrosis
- 1 January 1989
- journal article
- research article
- Published by Taylor & Francis in Experimental Lung Research
- Vol. 15 (6) , 801-812
- https://doi.org/10.3109/01902148909069627
Abstract
To assess the role of crystal size in biologic responses, we quantitated red blood cell lysis and lung inflammation and fibrosis in the mouse using 4 α-quartz preparations with average diameters of 1, 5, 7.8, and 11.2 μM. When compared on the basis of identical crystal surface areas, the 1-µm fraction was more hemolytic than the other 3 fractions. The three larger fractions had equivalent membranolytic activities. After 6 weeks of postintratracheal instillation of the crystals into mice, the 1-µm-diameter crystal fraction increased wet lung weights by 1.25 X that of saline controls, while a 1.75 X increase was found for the three larger crystal fractions. A similar response was found when evaluating fibrosis development by determining lung hydroxyproline levels. Measurement of the percentage of the crystal dose remaining in the lungs revealed that the biologic differences observed were not due to a difference in the clearance of the smaller crystal fraction. Thus, larger crystals of α-quartz produce a greater degree of inflammation and fibrosis when instilled into the lung than those of 1 4mUm diameter, even though the smaller crystals are more membranolytic in vitro and appear to be cleared from the lung at the same rate as the larger crystals.This publication has 20 references indexed in Scilit:
- Effect of the size and surface charge of polymer microspheres on their phagocytosis by macrophageBiomaterials, 1988
- Deposition and Retention Patterns for 3-, 9-, and 15-μm Latex Microspheres Inhaled by Rats and Guinea PigsExperimental Lung Research, 1988
- Types, numbers, sizes, and distribution of mineral particles in the lungs of urban male cigarette smokersEnvironmental Research, 1987
- Phagocytosis of latex particles by leucocytes. I. Dependence of phagocytosis on the size and surface potential of particlesBiomaterials, 1985
- Deposition and clearance of inhaled particles.Environmental Health Perspectives, 1984
- Silica-induced membranolysis: A study of different structural forms of crystalline and amorphous silica and the effects of protein adsorptionJournal of Colloid and Interface Science, 1982
- Pulmonary distribution of particles given by intratracheal instillation or by aerosol inhalationEnvironmental Research, 1976
- Experimental gouty synovitis caused by bacterial endotoxin adsorbed onto urate crystalsArthritis & Rheumatism, 1974
- PATHOGENIC EFFECTS OF INHALED PARTICLES AND ANTIGENSAnnals of the New York Academy of Sciences, 1974
- THE INFLUENCE OF THE SIZE OF QUARTZ DUST PARTICLES ON THE REACTION OF LUNG TISSUE*Annals of Occupational Hygiene, 1973