The influence of ambient magnetic environments on high-T c superconducting quantum interference device gradiometers
- 1 June 1996
- journal article
- research article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 79 (11) , 8783-8791
- https://doi.org/10.1063/1.362504
Abstract
The performance of high‐temperature superconducting gradiometers have been evaluated in fields of up to 70 μT to determine their limitations in unshielded environments. The sensors incorporate first‐order gradiometric superconducting quantum interference devices (SQUIDs) coupled to first‐order gradiometric flux transformers. A gradiometer was operated successfully at all angles with respect to an ambient field with less than 20% variation in critical current and voltage/flux ratio. Magnetic hysteresis at 77 K was measured for field excursions up to 70 μT. The hysteresis factor, referred to the SQUID, averaged 10−3 Φ0/μT. Flux movement in the SQUID washers rather than the flux transformer was found to be the dominant cause of the hysteresis and the presence of the flux transformer reduced the hysteresis. This is interpreted as due to the coupling coil pinning the vortices against radial motion. The spectral noise density of the gradiometer was only weakly dependent on the orientation with respect to static fields of up to 70 μT except for narrow angular ranges where dominating random telegraph signal processes occurred. In contrast, field cooling the gradiometer above 15 μT was found to substantially increase the low‐frequency noise. A gradiometer was successfully transported and operated out of doors with no shielding. Only a relatively minor degradation of performance was observed.This publication has 22 references indexed in Scilit:
- Superconducting magnetic sensors operating from a moving platformIEEE Transactions on Applied Superconductivity, 1995
- Eddy current evaluation of airframes using refrigerated SQUIDsIEEE Transactions on Applied Superconductivity, 1995
- Development of semi-portable DC-SQUID magnetometerIEEE Transactions on Applied Superconductivity, 1995
- High-T c three-axis dc SQUID magnetometer for geophysical applicationsReview of Scientific Instruments, 1994
- SQUIDs cross a watershedNature, 1994
- Effects of radio frequency radiation on the dc SQUIDApplied Physics Letters, 1994
- Low-frequency excess noise in YBa2Cu3O7−x dc superconducting quantum interference devices cooled in static magnetic fieldsApplied Physics Letters, 1994
- Three SQUID gradiometerApplied Physics Letters, 1993
- A YBa/sub 2/Cu/sub 3/O/sub 7/ thin film SQUID gradiometer for measurements in unshielded spaceIEEE Transactions on Applied Superconductivity, 1993
- Magnetic hysteresis in integrated low T c SQUID gradiometersApplied Physics Letters, 1991