The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip.
- 1 July 1995
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 77 (7) , 1058-1064
- https://doi.org/10.2106/00004623-199507000-00012
Abstract
-apex distance, is the sum of the distance from the tip of the lag screw to the apex of the femoral head on an anteroposterior radiograph and this distance on a lateral radiograph, after controlling for magnification. To determine the value of this measurement in the prediction of so-called cutout of the lag screw, 198 peritrochanteric fractures (193 patients) were studied. The minimum duration of follow-up was three months (average, thirteen months), during which period all of the fractures either healed or had failure of the fixation. Of the nineteen failures that were identified, sixteen were due to the device cutting out of the femoral head. The average tip-apex distance was twenty-four millimeters (range, nine to sixty-three millimeters) for the successfully treated fractures compared with thirty-eight millimeters (range, twenty-eight to forty-eight millimeters) for those in which the screw cut out (p = 0.0001). None of the 120 screws with a tip-apex distance of twenty-five millimeters or less cut out, but there was a very strong statistical relationship between an increasing tip-apex distance and the rate of cutout, regardless of all other variables related to the fracture.(ABSTRACT TRUNCATED AT 250 WORDS) Failure of fixation of peritrochanteric fractures that have been treated with a fixed-angle sliding hip-screw device is frequently related to the position of the lag screw in the femoral head. A simple measurement has been developed to describe the position of the screw. This measurement, the tip-apex distance, is the sum of the distance from the tip of the lag screw to the apex of the femoral head on an anteroposterior radiograph and this distance on a lateral radiograph, after controlling for magnification. To determine the value of this measurement in the prediction of so-called cutout of the lag screw, 198 peritrochanteric fractures (193 patients) were studied. The minimum duration of follow-up was three months (average, thirteen months), during which period all of the fractures either healed or had failure of the fixation. Of the nineteen failures that were identified, sixteen were due to the device cutting out of the femoral head. The average tip-apex distance was twenty-four millimeters (range, nine to sixty-three millimeters) for the successfully treated fractures compared with thirty-eight millimeters (range, twenty-eight to forty-eight millimeters) for those in which the screw cut out (p = 0.0001). None of the 120 screws with a tip-apex distance of twenty-five millimeters or less cut out, but there was a very strong statistical relationship between an increasing tip-apex distance and the rate of cutout, regardless of all other variables related to the fracture.(ABSTRACT TRUNCATED AT 250 WORDS) Copyright © 1995 by The Journal of Bone and Joint Surgery, Incorporated...Keywords
This publication has 27 references indexed in Scilit:
- The effect of complications after hip fracture on rehabilitationThe Journal of Bone and Joint Surgery. British volume, 1993
- Fixation of intertrochanteric fractures of the femur. A randomised prospective comparison of the gamma nail and the dynamic hip screwThe Journal of Bone and Joint Surgery. British volume, 1991
- Trochanteric FracturesPublished by Wolters Kluwer Health ,1990
- Intertrochanteric femoral fractures. Mechanical failure after internal fixationThe Journal of Bone and Joint Surgery. British volume, 1990
- Implant failures in patients with proximal fractures of the femur treated with a sliding screw deviceInjury, 1989
- Low Nail-plate Fixation and Early Weight-bearing Ambulation for Stable Trochanteric FracturesPublished by Wolters Kluwer Health ,1987
- Clinical Evaluation of the Sliding Compression Screw in 121 Hip FracturesSouthern Medical Journal, 1980
- TROCHANTERIC FRACTURES TREATED BY THE SLIDING SCREW PLATE FIXATION METHODPublished by Wolters Kluwer Health ,1964
- An Experimental Study on the Use of Nails and Bolt Screws in the Fixation of Fractures of the Femoral NeckActa Orthopaedica, 1961
- TROCHANTERIC FRACTURESThe Journal of Bone and Joint Surgery. British volume, 1951