Mitral Valve Repair With Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty Ring for Ischemic Mitral Regurgitation
- 4 July 2006
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Circulation
- Vol. 114 (1_suppleme) , I-588-I-593
- https://doi.org/10.1161/circulationaha.105.001347
Abstract
Background— Ischemic mitral regurgitation (IMR) is associated with asymmetric changes in annular and ventricular geometry. Surgical repair with standard symmetric annuloplasty rings results in a high incidence of residual or recurrent mitral regurgitation (MR). The Carpentier-McCarthy-Adams (CMA) IMR ETlogix annuloplasty ring is the first remodeling ring specifically designed to treat asymmetric leaflet tethering and annular dilatation. We used quantitative 2-dimensional echo to examine early results of mitral valve (MV) repair with the CMA IMR ETlogix annuloplasty ring in patients with IMR. Methods and Results— Fifty-nine patients (aged 68±12 years) with grade ≥2+ IMR (graded on a scale of 0 to 4+) underwent MV repair with the CMA IMR ETlogix annuloplasty ring. We assessed the mitral annular diameter (MAD), tethering area (TA), and tenting height (TH) of the MV in 4-chamber, 2-chamber, and long axis views at mid-systole before and 3 to 10 days after surgery. After surgery, 57 of 59 (97%) patients had grade 0 or 1+ MR, whereas 2 patients had 2+ MR. MV repair with the CMA IMR ETlogix ring significantly reduced MAD, TA, and TH ( P Conclusion— Surgical repair of IMR with the novel asymmetric CMA IMR ETlogix annuloplasty ring provided excellent early results with effective reduction of MR, MAD, and leaflet tethering. This novel etiology-specific strategy may result in improved outcomes in IMR patients.Keywords
This publication has 17 references indexed in Scilit:
- Recurrent mitral regurgitation after annuloplasty for functional ischemic mitral regurgitationThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Myocardial Rupture, Microvascular Obstruction, and Infarct ExpansionCirculation, 2003
- Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and doppler echocardiographyJournal of the American Society of Echocardiography, 2003
- Geometric Differences of the Mitral Apparatus Between Ischemic and Dilated Cardiomyopathy With Significant Mitral RegurgitationCirculation, 2003
- Ultrasonic Echolucent Carotid Plaques Predict Future StrokesCirculation, 2001
- Ischemic Mitral RegurgitationCirculation, 2001
- Mitral valve procedure in dilated cardiomyopathy: repair or replacement?The Annals of Thoracic Surgery, 2001
- Infarct Size And Location Determine Development Of Mitral Regurgitation In The Sheep ModelThe Journal of Thoracic and Cardiovascular Surgery, 1998
- Dynamic change in mitral regurgitant orifice area: comparison of color doppler echocardiographic and electromagnetic flowmeter-based methods in a chronic animal modelJournal of the American College of Cardiology, 1995
- Mechanism of ischemic mitral regurgitation. An experimental evaluation.Circulation, 1991