VVIR or DDD(R): Does it matter?
- 1 March 1991
- journal article
- review article
- Published by Wiley in Clinical Cardiology
- Vol. 14 (3) , 257-260
- https://doi.org/10.1002/clc.4960140315
Abstract
A continuing emphasis on cost effectiveness in health care may require that we use more expensive pacing systems only in situations where there is clear medical and scientific evidence of increased efficacy. Although dual-chamber and/or sensor-based, rate-modulating pacing systems are electronically no less reliable, they are part of a more complex pacing system. The requirement for two leads, one of which must maintain both pacing and sensing in the atrium, will inevitably impact the cost and reliability of such systems compared with a single-chamber ventricular system. Yet, there is clear evidence that AV synchrony is important at rest, particularly in patients susceptible to pacemaker syndrome, and there is mounting evidence that AV synchrony during exercise is beneficial independent of rate response. Finally, and perhaps most important, there is the suggestion that patient longevity may be extended by using pacing systems that preserve AV synchrony and/or minimize ventricular pacing.Keywords
This publication has 44 references indexed in Scilit:
- Long-term pacing in sinus node disease: Effects of stimulation mode on cardiovascular morbidity and mortalityAmerican Heart Journal, 1988
- The Importance of Different Atrioventricular Intervals for Exercise CapacityPacing and Clinical Electrophysiology, 1988
- Doppler echocardiographic assessment of the effect of varying atrioventricular delay and pacemaker mode on left ventricular fillingAmerican Heart Journal, 1988
- Atrial versus ventricular pacing in sinus node disease: A treatment comparison studyAmerican Heart Journal, 1986
- Maintenance of exercise stroke volume during ventricular versus atrial synchronous pacing: role of contractility.Circulation, 1985
- Reevaluation of the role of atrial systole to cardiac hemodynamics: Evidence for pulmonary venous regurgitation during abnormal atrioventricular sequencingAmerican Heart Journal, 1983
- A comparison of the acute and long-term hemodynamic effects of ventricular inhibited and atrial synchronous ventricular inhibited pacing.Circulation, 1982
- The influence of left ventricular filling pressure on atrial contribution to cardiac outputAmerican Heart Journal, 1979
- HAEMODYNAMIC EFFECT OF ATRIAL TRIGGERED VERSUS FIXED RATE PACING AT REST AND DURING EXERCISE IN COMPLETE HEART BLOCKActa Medica Scandinavica, 1975
- Studies on Starling's Law of the HeartCirculation, 1961