End‐to‐end electronic control of the hospital transfusion process to increase the safety of blood transfusion: strengths and weaknesses
- 1 March 2006
- journal article
- Published by Wiley in Transfusion
- Vol. 46 (3) , 352-364
- https://doi.org/10.1111/j.1537-2995.2006.00729.x
Abstract
Incorrect blood component transfused is a frequent serious incident associated with transfusion and often involves misidentification of the patient and/or the unit of blood. This study extended the evaluation of an electronic system involving bar code technology and handheld computers. Electronic control of collection of blood from blood refrigerators was incorporated into a previously described process for blood sample collection and blood administration. Practice was evaluated before and after its introduction in cardiac surgery. The baseline audits revealed poor practice. Significant improvements were found following the introduction of the electronic system, including from 8 percent to 100 percent in checking that the blood group and unit number on the blood pack matched the compatibility label and the pack was in date (p < or = 0.0001). Similar significant improvements were found in blood sample collection, the collection of blood from blood refrigerators, and the documentation of transfusion. Staff found the system easy to operate and preferred it to standard procedures. A bar code patient identification system improved transfusion practice, although areas for improvement were identified. These results provide support for further work on the development of such systems for both transfusion and other procedures requiring patient identification.Keywords
This publication has 15 references indexed in Scilit:
- Survey of the implementation of the recommendations in the Health Service Circular 2002/009 ‘Better Blood Transfusion’Transfusion Medicine, 2005
- A comprehensive assessment program to improve blood‐administering practices using the FOCUS–PDCA modelTransfusion, 2004
- Barcode technology: its role in increasing the safety of blood transfusionTransfusion, 2003
- Errors in Interpreting the Pretransfusion Bedside Compatibility TestVox Sanguinis, 2000
- The administration of blood and blood components and the management of transfused patientsTransfusion Medicine, 1999
- A cost-effectiveness analysis of the use of a mechanical barrier system to reduce the risk of mistransfusionTransfusion, 1996
- Bedside Transfusion Errors: Analysis of 2 Years' Use of a System to Monitor and Prevent Transfusion ErrorsVox Sanguinis, 1996
- A report of 104 transfusion errors in New York StateTransfusion, 1992
- Improvement in transfusion safety using a new blood unit and patient identification system as part of safe transfusion practiceTransfusion, 1991
- Fatalities from blood transfusionPublished by American Medical Association (AMA) ,1980