We report the results of 150 capsular bag implantations of the IOGEL PC-12 hydrogel lens. Mean follow-up was seven months. Following capsulorhexis and phacoemulsification, a Faulkner folder was used to insert the lens through a 3.5 mm to 4.0 mm scleral tunnel incision. Initially, a number of surgical complications were encountered. Because of increasing experience and modified instrumentation and technique, these did not occur in the later cases. Visual results were good, all eyes gaining a best case visual acuity of 20/40 or better and 97% achieving 20/25 or better. Morphological results were satisfactory. Generally the lenses remained centered and at a distance from the iris. Retention of viscoelastic substance or debris between the lens and the posterior capsule, occasionally observed at the start of the series, has been avoided by retrolental aspiration. Persistent pigment dispersion, which was observed when the lens had been implanted in the sulcus, was not seen. Tolerance of the lens material was generally satisfactory. There were six cases (4%) or fibrinoid uveitis, which is a relatively high incidence. From our experience and results we conclude that this implantation procedure allowed controlled insertion and placement of the IOGEL lens, provided that adequate instrumentation and technique was used; visual performance was comparable to that of poly(methyl methacrylate) lenses; capsular bag fixation furnished satisfactory morphological results, provided an adequately shaped capsulorhexis was performed.This publication has 14 references indexed in Scilit:
- Evaluation of the first 60 cases of poly HEMA posterior chamber lenses implanted in the sulcusJournal of Cataract & Refractive Surgery, 1989
- Drug uptake and release by a hydrogel intraocular lens and the human crystalline lensJournal of Cataract & Refractive Surgery, 1989
- Folding and inserting silicone intraocular lens implantsJournal of Cataract & Refractive Surgery, 1987
- Neodymium:YAG laser interaction with Alcon IOGEL hydrogel intraocular lenses: An in vitro toxicity assayJournal of Cataract & Refractive Surgery, 1987
- Evaluation of 50 silicone posterior chamber lens implantationsJournal of Cataract & Refractive Surgery, 1987
- Capsular bag implantation of the hydrogel lensJournal of Cataract & Refractive Surgery, 1987
- Clinical results of hydrogel lens implantationJournal of Cataract & Refractive Surgery, 1986
- Corneal Endothelial Loss with New Intraocular LensesAmerican Journal of Ophthalmology, 1984
- Preliminary study of hydrophilic hydrogel intraocular lens implants in catsAmerican Intra-Ocular Implant Society Journal, 1984
- Poly-HEMA as a material for intraocular lens implantation: a preliminary report.British Journal of Ophthalmology, 1981