Abstract
Partially denaturing high‐performance liquid chromatography has emerged as the most sensitive physical mutation scanning method. However, there are a few reports of mutations missed or only detectable at unique temperatures. The combined use of ion‐pair reversed‐phase high‐performance liquid chromatography under completely denaturing conditions and electrospray ionization quadrupole ion trap mass spectrometry (ICEMS) obviates the need for selecting appropriate temperatures for resolving heteroduplices and allows the discrimination of different alleles even when they co‐elute due to distinct mass differences between nucleobases. This was demonstrated for the detection of four mutations (259G>A, 286A>G, 300T>G, and 331+1G>A) in exon 5 and intron 5 of BRCA1, respectively. Current mass resolution of quadrupole ion trap mass spectrometers limits the identification of single A>T or T>A transversions with a mass difference of 9 Da to fragments <80 base pairs (bp). The presence of all other mutations can be detected in fragments up to approximately 105 bp. The approach may prove particularly useful in the mutational scanning of AT‐ or GC‐rich sequences that are recalcitrant to most other methods. Hum Mutat 21:86–95, 2002.Keywords
This publication has 31 references indexed in Scilit:
- Interpreting epidemiological research: blinded comparison of methods used to estimate the prevalence of inherited mutations in BRCA1Journal of Medical Genetics, 2001
- Mutation Detection Using Mass Spectrometric Separation of Tiny Oligonucleotide FragmentsGenome Research, 2001
- Denaturing high-performance liquid chromatography: A reviewHuman Mutation, 2001
- Electrospray ionization mass spectrometry of oligonucleotide complexes with drugs, metals, and proteinsMass Spectrometry Reviews, 2001
- Analysis of nucleic acids by on‐line liquid chromatography–Mass spectrometryMass Spectrometry Reviews, 2001
- Denaturing High-Performance Liquid Chromatography Detects Reliably BRCA1 and BRCA2 MutationsGenomics, 1999
- Analysis of Nucleic Acids by Capillary Ion-Pair Reversed-Phase HPLC Coupled to Negative-Ion Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 1999
- A Sequencing Method Based on Real-Time PyrophosphateScience, 1998
- Analysis of Oligonucleotides by HPLC−Electrospray Ionization Mass SpectrometryAnalytical Chemistry, 1997
- Practical methods of mutation detectionCurrent Opinion in Genetics & Development, 1996