The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: A Monte Carlo study†
Top Cited Papers
- 26 March 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 51 (4) , 807-815
- https://doi.org/10.1002/mrm.20033
Abstract
There are conflicting opinions in the literature as to whether it is more beneficial to use a large number of gradient sampling orientations in diffusion tensor MRI (DT‐MRI) experiments than to use a smaller number of carefully chosen orientations. In this study, Monte Carlo simulations were used to study the effect of using different gradient sampling schemes on estimates of tensor‐derived quantities assuming a b‐value of 1000 smm–2. The study focused in particular on the effect that the number of unique gradient orientations has on uncertainty in estimates of tensor‐orientation, and on estimates of the trace and anisotropy of the diffusion tensor. The results challenge the recently proposed notion that a set of six icosahedrally‐arranged orientations is optimal for DT‐MRI. It is shown that at least 20 unique sampling orientations are necessary for a robust estimation of anisotropy, whereas at least 30 unique sampling orientations are required for a robust estimation of tensor‐orientation and mean diffusivity. Finally, the performance of sampling schemes that use low numbers of sampling orientations, but make efficient use of available gradient power, are compared to less efficient schemes with larger numbers of sampling orientations, and the relevant scenarios in which each type of scheme should be used are discussed. Magn Reson Med 51:807–815, 2004. Published 2004 Wiley‐Liss, Inc.Keywords
This publication has 23 references indexed in Scilit:
- Non-invasive mapping of connections between human thalamus and cortex using diffusion imagingNature Neuroscience, 2003
- Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRIMagnetic Resonance in Medicine, 2002
- Estimation of anatomical connectivity from diffusion tensor dataNeuroImage, 2001
- Condition Number as a Measure of Noise Performance of Diffusion Tensor Data Acquisition Schemes with MRIJournal of Magnetic Resonance, 2000
- Minimal gradient encoding for robust estimation of diffusion anisotropy☆Magnetic Resonance Imaging, 2000
- Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imagingMagnetic Resonance in Medicine, 1999
- In vivo measurement of T2 distributions and water contents in normal human brainMagnetic Resonance in Medicine, 1997
- Toward a quantitative assessment of diffusion anisotropyMagnetic Resonance in Medicine, 1996
- MR diffusion tensor spectroscopy and imagingBiophysical Journal, 1994
- Early detection of regional cerebral ischemia in cats: Comparison of diffusion‐ and T2‐weighted MRI and spectroscopyMagnetic Resonance in Medicine, 1990