Clinical Evaluation of a Continuous Minimally Invasive Glucose Flux Sensor Placed over Ultrasonically Permeated Skin
- 1 February 2004
- journal article
- clinical trial
- Published by Mary Ann Liebert Inc in Diabetes Technology & Therapeutics
- Vol. 6 (1) , 21-30
- https://doi.org/10.1089/152091504322783378
Abstract
Frequent monitoring and tight metabolic control of blood glucose levels can reduce microvascular complications and subsequent co-morbidities in patients with diabetes. Self-monitoring with finger sticks provides intermittent data at best, and results in poor compliance. We report on a minimally invasive system that continually measures glucose flux through ultrasonically permeated skin. Ten patients with diabetes were enrolled in a clinical study to determine correlation between data collected by glucose biosensors placed over ultrasonically treated skin sites (two per patient), and blood glucose readings were taken every 20 min over an 8-h period. Glucose flux biosensors measured amperometric current proportional to hydrogen peroxide level, generated from catalytic conversion of glucose by glucose oxidase; the sensor was coupled to the skin by a thin hydrogel containing an osmotic extraction buffer, creating a gradient for glucose transport through the skin. The biosensors were attached to small portable meters that recorded time, current, and temperature readings every 5 s. At the conclusion of the study period, meter recordings were downloaded for data processing. Skin sites were examined for irritation due to biosensor contact. Data from glucose biosensors with completed data sets had a correlation coefficient of 0.84, and 95% of the data pairs (n = 241) were in the A + B region of a Clarke error grid. Ultrasonic pretreatment lasting about 10 s resulted in improved conductance in all patients. No patients complained of pain or irritation at any time during the study. Continuous monitoring of glucose flux through ultrasonically permeable skin is safe and feasible.Keywords
This publication has 14 references indexed in Scilit:
- Analysis: Dawn of Real-Time Continuous Glucose SensingDiabetes Technology & Therapeutics, 2003
- Analysis of Continuous Glucose Monitoring Data from Non-Diabetic and Diabetic Children: A Tale of Two AlgorithmsDiabetes Technology & Therapeutics, 2003
- Glucose Sensor Evaluation of Glycemic Instability in Pediatric Type 1 Diabetes MellitusDiabetes Technology & Therapeutics, 2003
- Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin AnalogsDiabetes Care, 2003
- Glucose monitoring by reverse iontophoresisDiabetes/Metabolism Research and Reviews, 2002
- Limitations of Conventional Methods of Self-Monitoring of Blood GlucoseDiabetes Care, 2001
- Noninvasive Glucose MonitoringJAMA, 1999
- United Kingdom Prospective Diabetes Study 24: A 6-Year, Randomized, Controlled Trial Comparing Sulfonylurea, Insulin, and Metformin Therapy in Patients with Newly Diagnosed Type 2 Diabetes That Could Not Be Controlled with Diet TherapyAnnals of Internal Medicine, 1998
- IntroductionDiabetes Care, 1996
- The Effect of Intensive Treatment of Diabetes on the Development and Progression of Long-Term Complications in Insulin-Dependent Diabetes MellitusNew England Journal of Medicine, 1993