Determination of oxygen-containing additives in gasoline by gas chromatography–microwave-induced plasma atomic emission spectrometry
- 1 January 1994
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 9 (2) , 73-78
- https://doi.org/10.1039/ja9940900073
Abstract
The development and characterization of a method for the determination of oxygen-containing (oxygenated) species in a complex mixture of hydrocarbons is described. A microwave-induced plasma (MIP) atomic emission detector is coupled to a gas chromatograph, and atomic oxygen emission is monitored as an indication of oxygenated compounds in the gas chromatograph effluent. On-line helium purification and the use of a tangential-flow torch provide conditions ideal for oxygen-selective analysis without make-up gases or extensive background correction. Furthermore, large amounts of solvent or sample do not extinguish the plasma so samples can be analysed directly without dilution, addition of reagent gases or solvent venting procedures. Both axial and lateral viewing positions were investigated for analytical use. Detection limits for oxygen were 1 ng s–1 for both axial and lateral positions but sensitivity was higher in the axial position. However, selectivity over carbon in the lateral position was 4850 : 1 compared with 155 : 1 in the axial position. The gas chromatography MIP method was applied, using lateral viewing, to the analysis of alcohols in National Institute of Standards and Technology (NIST) reference fuel standards and to commercial gasoline samples collected from Columbia, SC, USA and Greensboro, NC, USA. Experimental results of oxygen-selective analysis of NIST reference fuel are in good agreement with the certified values. Results obtained for the determination of oxygenated compounds in gasoline samples further demonstrate the usefulness of the method for the analysis of a complex mixture of hydrocarbons. Most spike recoveries were within 10% of the expected values. Examples of oxygen-selective chromatograms are presented to demonstrate the usefulness and selectivity of the method.Keywords
This publication has 15 references indexed in Scilit:
- Determination of ethers and alcohols in gasolines by gas chromatography/Fourier transform infrared spectroscopyAnalytical Chemistry, 1992
- Determination of Oxygenates in Gasoline Range Hydrocarbons by Capillary Column Gas Chromatography: A User's Experience with an Oxygen-Specific Detector (OFID)Journal of Chromatographic Science, 1990
- Oxygen-selective microwave-induced plasma gas chromatography detector for petroleum-related samplesAnalytical Chemistry, 1988
- Selective determination of oxygenates in complex samples with the O‐FID analyzerJournal of High Resolution Chromatography, 1988
- Consideration of an atmospheric pressure microwave-induced helium plasma as an oxygen-selective gas chromatographic detectorJournal of Chromatography A, 1986
- Use of a tangential-flow torch with a microwave-induced plasma emission detector for gas chromatographySpectrochimica Acta Part B: Atomic Spectroscopy, 1985
- Analysis of oxygenated compounds by gas chromatography-microwave plasma emission spectrometrySpectrochimica Acta Part B: Atomic Spectroscopy, 1985
- A Critical Evaluation of the Tangential Flow Torch Microwave-Induced Plasma Detector for Gas ChromatographyApplied Spectroscopy, 1983
- Considerations in the design of a microwave induced plasma utilizing the TM010 cavity for optical emission spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 1981