In vivo biocompatibility studies. VII. Inflammatory response to polyethylene and to a cytotoxic polyvinylchloride
- 1 January 1986
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 20 (1) , 37-50
- https://doi.org/10.1002/jbm.820200105
Abstract
The cellular biocompatibility of low‐density polyethylene and a cytotoxic polyvinylchloride were investigated using an in vivo cage implant system. Components of the inflammatory response (white cells, extracellular alkaline and acid phosphatase, the complement component C3, and total protein content) were monitored over a 21‐day implantation period. Scanning electron microscopy was used to evaluate the morphologic condition of leukocytes adherent to the implanted polymers. Prior to implantation, each polymer was evaluated using an established primary acute toxicity screen. The results showed that the cytotoxic polyvinylchloride stimulated an intense acute phase inflammatory response, and at later observation periods, an intense and increasing chronic inflammatory response. In constrast, the polyethylene promoted relatively small increases in the acute and chronic phases of inflammation; the overall cellular response being essentially resolved by the third week after implantation. The initial toxicity screen of each polymer suggested that the observed differences in inflammation were primarily caused by the release from the polyvinylchloride of the added cytotoxic agent (dioctyltinbisoctylmercaptoacetate).This publication has 23 references indexed in Scilit:
- Changes concerning the external structure of peritoneal macrophages, due to the DQ-12 standard dustEnvironmental Research, 1983
- BiocompatMity screening of poly (vinyl chloride) implantsBiomaterials, 1982
- Methodological assessments of subcutaneous implantation techniquesJournal of Biomedical Materials Research, 1980
- The effect of different mineral dusts on the mechanism of phagocytosis: A scanning electron microscope studyEnvironmental Research, 1978
- Toxicological Evaluation of Biomaterials: Primary Acute Toxicity Screening ProgramArtificial Organs, 1977
- Cellular enzyme activity at the polymer–tissue interface: A reviewJournal of Biomedical Materials Research, 1976
- Biocompatibility of materials for total joint replacementJournal of Biomedical Materials Research, 1976
- Concanavalin A and the in vitro induction in macrophages of vacuolation and lysosomal enzyme synthesisExperimental Cell Research, 1975
- AN EXAMINATION OF THE CYTOTOXIC EFFECTS OF SILICA ON MACROPHAGESThe Journal of Experimental Medicine, 1966