Respiratory phase detection and delay determination for breath-by-breath analysis
- 1 February 1987
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 62 (2) , 837-843
- https://doi.org/10.1152/jappl.1987.62.2.837
Abstract
The delay between air flow and gas concentration signals is generally assumed to be constant within a breath as well as from breath to breath, but it was not possible to examine the constancy of the delay with the delay determination techniques so far available. Thus we developed new methods for respiratory phase detection and delay determination. The presented algorithm for the detection of the start of inspiration and expiration (phase detection) replaces the generally used valve assembly with two pneumotachographs. Now, the pneumotachograph is used in a bidirectional mode, but with a volume criterion for phase detection replacing the less reliable threshold criterion. To measure the delay between flow and gas concentration signals, a test gas is periodically injected as a marker. This test gas contains less N2 than ambient air. Therefore, the delay is determined as time between the moment of injection and the drop of N2. These two methods rendered it possible to examine delay variations and their consequences. The investigation of various breathing patterns demonstrated that the usually assumed errors caused by delay uncertainty are underestimated. We suggest reliance on a breath-by-breath delay determination to account for delay variations.This publication has 11 references indexed in Scilit:
- Alveolar gas exchange during exercise: a single-breath analysisJournal of Applied Physiology, 1984
- A pulsed phase measurement ultrasonic flowmeter for medical gasesAnnals of Biomedical Engineering, 1984
- Breath-by-breath VCO2 and VO2 required compensation for transport delay and dynamic responseJournal of Applied Physiology, 1982
- Breath-by-breath measurement of true alveolar gas exchangeJournal of Applied Physiology, 1981
- Corrections for the response time and delay of mass spectrometersJournal of Applied Physiology, 1981
- A piston pump for respiration simulationJournal of Applied Physiology, 1981
- Incorporating the gas analyzer response time in gas exchange computationsJournal of Applied Physiology, 1979
- Breath-by-breath variation of FRC: effect on VO2 and VCO2 measured at the mouthJournal of Applied Physiology, 1979
- Aspects of on-line digital integration of pulmonary gas transferJournal of Applied Physiology, 1977
- Wasserdampfunabh ngige Probeneinla systeme f r RespirationsmassenspektrometerPflügers Archiv - European Journal of Physiology, 1968