In situ diagnosis of intravascular catheter-related bloodstream infection: A comparison of quantitative culture, differential time to positivity, and endoluminal brushing
- 1 April 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 33 (4) , 787-791
- https://doi.org/10.1097/01.ccm.0000157968.98476.f3
Abstract
To compare the accuracy of three techniques that do not require central venous catheter removal to diagnose catheter-related bloodstream infection. Prospective cohort study of central venous catheters from suspected cases of catheter-related bloodstream infection. University teaching hospital. One hundred and twenty-five central venous catheters from patients with suspected catheter-related bloodstream infection (a raised peripheral white blood cell count, temperature >37°C, and/or local signs of infection at the catheter skin entry site) in intensive care and surgical patients in a large teaching hospital were assessed. None. Three techniques were compared: the differential time to positivity of central venous catheter vs. peripheral-blood cultures, quantitative culture of central venous catheter vs. peripheral blood, and the endoluminal brush with peripheral blood culture. Central venous catheters with a median dwell time of 11 days were examined. There were 36 episodes of catheter-related bloodstream infection, defined as a positive result from at least two of the three tests in the presence of a peripheral blood culture growing the same microorganism and without an identifiable alternative source of sepsis. The sensitivities of the endoluminal brush, quantitative culture, and differential time to positivity techniques were 100%, 89%, and 72%, respectively, with corresponding specificities of 89%, 97%, and 95%. Blood could be directly aspirated from only 231 of 312 (74%) lumens. In the 20 cases of catheter-related bloodstream infection associated with multiple-lumen central venous catheters, endoluminal brushing was positive for one, two, and three lumens in nine (45%), six (30%), and five (25%) cases, respectively. All three techniques had relatively high sensitivity. However, inability to obtain samples via central venous catheters is a major drawback of the differential time to positivity and quantitative blood culture approaches. Differential time to positivity is simple to perform and has high specificity and therefore could be used as a first line approach, with the endoluminal brush reserved for cases where blood cannot be obtained. All lumens of multiple-lumen central venous catheters must be sampled to ensure maximal sensitivity.Keywords
This publication has 19 references indexed in Scilit:
- The epic Project: Developing National Evidence-based Guidelines for Preventing Healthcare associated InfectionsJournal of Hospital Infection, 2001
- Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood culturesThe Lancet, 1999
- Intravascular-catheter-related infectionsThe Lancet, 1998
- Prevention of Central Venous Catheter-Related Bloodstream Infection by Use of an Antiseptic-Impregnated CatheterAnnals of Internal Medicine, 1997
- Evaluation of a novel endoluminal brush method for in situ diagnosis of catheter related sepsis.Journal of Clinical Pathology, 1997
- Rapid diagnosis of central venou catheter sepsisThe Lancet, 1993
- The Clinical Impact of Culturing Central Venous CathetersArchives of internal medicine (1960), 1992
- Value of differential quantitative blood cultures in the diagnosis of catheter-related sepsisEuropean Journal of Clinical Microbiology & Infectious Diseases, 1992
- A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related InfectionNew England Journal of Medicine, 1977
- Catheter Complications in Total Parenteral NutritionNew England Journal of Medicine, 1974