Flow cytometric quantitative determination of ingestion by phagocytes needs the distinguishing of overlapping populations of binding and ingesting cells
Open Access
- 10 May 2005
- journal article
- research article
- Published by Wiley in Cytometry Part A
- Vol. 65A (2) , 93-102
- https://doi.org/10.1002/cyto.a.20139
Abstract
Background: The use of flow cytometry with fluorescently labeled particles provides the means to examine quantitatively the phagocytotic capacity of an individual phagocyte. This report describes an improved flow cytometric method of analysis for kinetic measurement of phagocytosis of fluorescein isothiocyanate (FITC)–labeled zymosan particles by human leukocytes.Methods: FITC‐labeled zymosan was incubated with leukocyte suspension, and at selected time intervals fluorescence positive neutrophils were divided by phagocytotic gates into three subpopulations: neutrophils that were neither binding nor ingesting particles, neutrophils that were only binding particles (binding cells), and neutrophils that were binding and ingesting particles (ingesting cells). For the distinction between internalized and surface‐bound FITC‐labeled zymosan, trypan blue (1.2 mg/ml) was used to quench surface‐bound fluorescence.Results: The technical challenges related to settings of phagocytotic gates and derivation of phagocytotic equations were presented. From 28 control samples, numerical values of mean fluorescence intensities and percentages of phagocytotic subpopulations inside phagocytotic gates before and after quenching were inserted into phagocytotic equations and corrected phagocytotic parameters were calculated. Calculated parameters were surprisingly constant across individuals.Conclusions: Essential elements of the present method appeared to be partial quenching of extracellular fluorescence with trypan blue and distinguishing between overlapping populations of binding and ingesting cells. Corrections using derived phagocytotic equations proved necessary for accurate kinetic phagocytotic measurements. Corrections were less necessary when the ingestion process was finished.Keywords
This publication has 37 references indexed in Scilit:
- Opsonization and Phagocytosis ofPlasmodium falciparumMerozoites Measured by Flow CytometryClinical and Diagnostic Laboratory Immunology, 2000
- Flow cytometric quantitation of human opsonin-dependent phagocytosis and oxidative burst responses to meningococcal antigensCytometry, 1998
- Flow cytometry distinction between adherent and phagocytized yeast particlesCytometry, 1994
- Flow cytometric assay for phagocytosis of human monocytes mediated via Fcγ-receptors and complement receptor CR1 (CD35)Cytometry, 1991
- Simultaneous flow cytometric method to measure phagocytosis and oxidative products by neutrophilsCytometry, 1991
- Flow cytometric assay for the measurement of human bone marrow phenotype, function and cell cycleCytometry, 1990
- Light-scattering polarization measurements as a new parameter in flow cytometryCytometry, 1987
- Processing of staphylococcus aureus and zymosan particles by human leukocytes measured by flow cytometryCytometry, 1984
- Phagolysosomal pH of human neutrophilsBlood, 1984
- Simultaneous measurement of phagocytosis and phagosomal pH by flow cytometry: Role of polymorphonuclear neutrophilic leukocyte granules in phagosome acidificationCytometry, 1983