Tracheoesophageal Fistula Caused by Cuffed Tracheal Tube
- 1 March 1978
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 113 (3) , 338-340
- https://doi.org/10.1001/archsurg.1978.01370150110028
Abstract
• A tracheoesophageal fistula secondary to prolonged nasogastric intubation and ventilatory assistance via a cuffed tracheostomy tube developed in a 27-year-old woman who had sustained a traumatic injury. The fistula grew progressively larger despite removal of the tubes, thus demonstrating the inherent poor prognosis associated with the untreated lesion. Since the cuff necessarily damages the trachea circumferentially at the same level, closure of the fistula and circumferential excision and reconstruction of the damaged tracheal wall were performed with an excellent result up to four years after the repair. This would be the preferred procedure when the patient can be weaned off the respirator and when the general condition and the size of the fistula allow such a definitive one-stage approach. (Arch Surg 113:338-340, 1978)This publication has 6 references indexed in Scilit:
- Repair of Inflammatory Tracheoesophageal FistulaThe Annals of Thoracic Surgery, 1976
- Management of tracheoesophageal fistula caused by cuffed tracheal tubesThe American Journal of Surgery, 1972
- Ulcerative tracheo-oesophageal fistula during treatment by tracheostomy and intermittent positive pressure ventilationThorax, 1972
- Tracheoesophageal Fistulas Following Prolonged Artificial Ventilation via Cuffed Tracheostomy TubesAnesthesiology, 1969