Improved Temporal Resolution for in Vivo Microdialysis by Using Segmented Flow
- 12 June 2008
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 80 (14) , 5607-5615
- https://doi.org/10.1021/ac800622s
Abstract
Microdialysis sampling probes were interfaced to a segmented flow system to improve temporal resolution for monitoring concentration dynamics. Aqueous dialysate was segmented into nanoliter plugs by pumping sample stream into the base of a tee channel structure microfabricated on a PDMS chip that had an immiscible carrier phase (perfluorodecalin) pumped into the cross arm of the tee. Varying the oil flow rate from 0.22 to 6.3 μL/min and sample flow rate from 42 to 328 nL/min allowed control of plug volume, interval between plugs, and frequency of plug generation between 6 and 28 nL, 0.6 and 10 s, and 0.1 and 1.7 Hz, respectively. Temporal resolution of the system, determined by measuring fluorescence in individual sample plugs following step changes of fluorescein concentration at the sampling probe surface, was as good as 15 s. Temporal resolution was independent of both sampling flow rate and distance that samples were pumped from the sampling probe. This effect is due to the prevention of Taylor dispersion of the sample as it was transported by segmented flow. In contrast, without flow segmentation, temporal resolution was worsened from 25 to 160 s as the detection point was moved from the sampling probe to 40 cm downstream. Glucose was detected by modifying the chip to allow enzyme assay reagents to be mixed with dialysate as sample plugs formed. The resulting assay had a detection limit of 50 μM and a linear range of 0.2−2 mM. This system was used to measure glucose in the brain of anesthetized rats. Basal concentration was 1.5 ± 0.1 mM (n = 3) and was decreased 60% by infusion of high-K+ solution through the probe. These results demonstrate the potential of microdialysis with segmented flow to be used for in vivo monitoring experiments with high temporal resolution.Keywords
This publication has 59 references indexed in Scilit:
- Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cellsProceedings of the National Academy of Sciences, 2008
- Control and Measurement of the Phase Behavior of Aqueous Solutions Using MicrofluidicsJournal of the American Chemical Society, 2007
- Using a Multijunction Microfluidic Device To Inject Substrate into an Array of Preformed Plugs without Cross-Contamination: Comparing Theory and ExperimentsAnalytical Chemistry, 2007
- On-Chip Titration of an Anticoagulant Argatroban and Determination of the Clotting Time within Whole Blood or Plasma Using a Plug-Based Microfluidic SystemAnalytical Chemistry, 2006
- Dynamic Changes in Brain Glucose and Lactate in Pericontusional Areas of the Human Cerebral Cortex, Monitored with Rapid Sampling On-Line Microdialysis: Relationship with Depolarisation-Like EventsJournal of Cerebral Blood Flow & Metabolism, 2005
- Screening of Protein Crystallization Conditions on a Microfluidic Chip Using Nanoliter-Size DropletsJournal of the American Chemical Society, 2003
- Formation of Droplets and Mixing in Multiphase Microfluidics at Low Values of the Reynolds and the Capillary NumbersLangmuir, 2003
- Soft Lithography in Biology and BiochemistryAnnual Review of Biomedical Engineering, 2001
- Extracellular Glucose Concentrations in the Rat Hippocampus Measured byZero‐Net‐FluxJournal of Neurochemistry, 1999
- Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)Analytical Chemistry, 1998