A reciprocating magnetic refrigerator for 2–4 K operation: Initial results
- 1 September 1979
- journal article
- research article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 50 (9) , 5870-5877
- https://doi.org/10.1063/1.326683
Abstract
The basic theory and design of a reciprocating magnetic refrigerator to pump heat from 2.2 to 4.2 K is presented. The results of initial experiments are shown. These results include conduction losses, eddy current losses, frictional losses, and mixing losses. Two cooling cycles were attempted and a net cooling power of 52 mW was observed at 1/60 Hz. The key problems in this design are identified and discussed.This publication has 15 references indexed in Scilit: