Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings
- 1 January 2005
- journal article
- Published by Hindawi Limited in Indoor Air
- Vol. 15 (1) , 19-26
- https://doi.org/10.1111/j.1600-0668.2004.00313.x
Abstract
Our study conducted serial environmental measurements in 12 large office buildings with two different ventilation designs to obtain airborne microbial concentrations in typical office buildings, and to examine the effects of occupant density, ventilation type and air exchange efficiency on indoor microbial concentrations. Duplicate samples of airborne fungi and bacteria, a total of 2477 measurements, were collected based on a scheme of conducting sampling three times a day for at least seven consecutive days at every study building. Air change rates (ACHs) were also estimated by tracer gas concentration decay method, and measured by continuous Multi-Gas monitor for each building. Most sampling sites were with total fungal and bacteria concentrations higher than 1000 CFU/m(3), an often-quoted guideline in earlier research. Significantly higher concentrations of fungi and bacteria, as well as higher indoor/outdoor (I/O) ratios across most groups of airborne microbes, were identified in buildings with fan coil unit (FCU) system than those with air-handling unit (AHU) system (Student's t test, P < 0.0001). Older buildings and higher air exchange rates were statistically associated with greater indoor bacteria levels in FCU ventilated buildings (R(2) = 0.452); a pattern not found in AHU buildings. Increasing ACH seemed to be the determinant factor for rising indoor fungal and Cladosporium concentrations in those FCU buildings (R(2) = 0.346; 0.518). Our data indicated that FCU ventilated buildings might have provided more outdoor matters into indoor environments through direct penetration of outdoor air. Results also demonstrated a quantitative association between rising numbers of occupants and increasing indoor levels of yeast in both FCU and AHU ventilated buildings. The regression model identified in this study may be considered a reference value for proposing an optimal ACH, while with adequate filtration of fresh air, as an effective strategy in lowering indoor microbial concentrations in air-conditioned buildings. As control of indoor microbial contamination has become an increasing concern around the world, feasibility and effectiveness of adopting ventilation approach has attracted a significant interest. This field investigation demonstrated, quantitatively, critical variables to be taken into consideration while applying such a measure, including the kinds of microbes to be removed and the types of ventilation system already in place.Keywords
This publication has 28 references indexed in Scilit:
- Indoor Health: Background Levels of FungiAihaj Journal, 2003
- The Ability of Hospital Ventilation Systems to FilterAspergillusand Other Fungi Following a Building ImplosionInfection Control & Hospital Epidemiology, 2002
- Profiles of Airborne Fungi in Buildings and Outdoor Environments in the United StatesApplied and Environmental Microbiology, 2002
- Indoor biological contaminants and symptoms of sick building syndrome in office buildings in MauritiusInternational Journal of Environmental Health Research, 2002
- Dampness in Buildings and HealthIndoor Air, 2001
- Exposure Assessment of Indoor Allergens, Endotoxin, and Airborne Fungi for Homes in Southern TaiwanEnvironmental Research, 2001
- Indoor Pollution and Sick Building Syndrome Symptoms among Workers in Day-Care CentersArchives of environmental health, 1997
- Airborne Fungus Allergen in Association with Residential Characteristics in Atopic and Control Children in a Subtropical RegionArchives of environmental health, 1997
- Associations between questionnaire reports of home dampness and childhood respiratory symptomsScience of The Total Environment, 1992
- Pathogenic fungi in human dwellings*Mycoses, 1992