Estimation of chromium-51 ethylene diamine tetra-acetic acid plasma clearance: a comparative assessment of simplified techniques
- 1 January 1992
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 19 (1) , 30-35
- https://doi.org/10.1007/bf00178305
Abstract
Chromium-51 ethylene diamine tetra-acetic acid (51Cr-EDTA) total plasma clearance was evaluated using a multi-sample method (i.e. 12 blood samples) as the reference compared with several simplified methods which necessitated only one or few blood samples. The following 5 methods were evaluated: terminal slope-intercept method with 3 blood samples, simplified method of Bröchner-Mortensen and 3 single-sample methods (Constable, Christensen and Groth, Tauxe). Linear regression analysis was performed. Standard error of estimate, bias and imprecision of different methods were evaluated. For 51Cr-EDTA total plasma clearance greater than 30 ml · min−1, the results which most approximated the reference source were obtained by the Christensen and Groth method at a sampling time of 300 min (inaccuracy of 4.9%). For clearances between 10 and 30 ml · min−1, single-sample methods failed to give reliable results. Terminal slope-intercept and Bröchner-Mortensen methods were better, with inaccuracies of 17.7% and 16.9%, respectively. Although sampling times at 180, 240 and 300 min are time-consuming for patients, 51Cr-EDTA total plasma clearance can be accurately calculated for values greater than 10 ml · min−1 using the Bröchner-Mortensen method. In patients with clearance greater than 30 ml · min−1, single-sample techniques provide a good alternative to the multi-sample method; the choice of the method to be used depends on the degree of accuracy required.Keywords
This publication has 16 references indexed in Scilit:
- Measurement of glomerular filtration rate in adults: accuracy of five single‐sample plasma clearance methodsClinical Physiology and Functional Imaging, 1989
- A method for the calculation of renal clearance based on a single plasma sampleClinical Physiology and Functional Imaging, 1983
- 51Cr‐EDTA clearance determined by one plasma sampleClinical Physiology and Functional Imaging, 1981
- Single Sample Estimates of Renal ClearancesBritish Journal of Urology, 1979
- Routine methods and their reliability for assessment of glomerular filtration rate in adults, with special reference to total [51Cr]EDTA plasma clearance.1978
- Comparison between total and renal plasma clearance of [51Cr] EDTA.1976
- Glomerular filtration rate estimation based on a single blood sample.BMJ, 1975
- A Simple Method for the Determination of Glomerular Filtration RateScandinavian Journal of Clinical and Laboratory Investigation, 1972
- Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA.1969
- Renal Inulin Clearance versus Total Plasma Clearance of51Cr-EDTAScandinavian Journal of Clinical and Laboratory Investigation, 1969