Interference from 2,3,5,6-3?,4?-Hexachlorobiphenyl (CB 163) in the Determination of 2,3,4-2?,4?,5?-Hexachlorobiphenyl (CB 138) in Environmental and Technical Samples
- 1 September 1990
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 40 (1) , 59-68
- https://doi.org/10.1080/03067319008030518
Abstract
In Intern. J. Enuiron. Anal. Chem. 66 (1989), 155-161, Roos et al.1 reported on problems encountered in the determination of 2,3,4-2′,4′,5′-hexachlorobiphenyl (CB 138) in environmental samples. These authors indicated that an interference was present for the capillary column gas chromatographic (HRGC) determination of CB 138. This interference was tentatively identified (without standard) as 2,3,5,6-3′,4′-hexachlorobiphenyl (CB 163). We have synthesized CB 163 and can confirm that it co-elutes with CB-138 on the widely used HRGC phase for polychlorinated biphenyl (PCB) analysis, 5%, phenyl, 95% methylpolysiloxane (CP-SIL8-CB) even on a 50m column. However, we managed to separate CB 163 from CB 138 on the very polar phase, bis-cyanopropylphenyl polysiloxane (SP-2330), using a 30 m column. We have quantified CB 163 and CB 138 in various environmental and technical samples and have found CB 163 to CB 138 ratios from I: 10 up to 3: 10.Keywords
This publication has 8 references indexed in Scilit:
- Organochlorine compounds and PCB congeners in contaminated sedimentsScience of The Total Environment, 1989
- Problems Encountered in the Determination of 2,3,4-2′4′5′ Hexachlorobiphenyl (CB 138) in Environmental SamplesInternational Journal of Environmental Analytical Chemistry, 1989
- A two-dimensional reaction gas chromatography system for isomer-specific determination of polychlorinated biphenylsChemosphere, 1989
- Multidimensional gas chromatography with electron capture detection for the determination of toxic congeners in polychlorinated biphenyl mixturesAnalytical Chemistry, 1988
- Dicholorbenzyl alkyl ether homologs as retention index markers and internal standards for the analysis of environmental samples using capillary gas chromatographyJournal of High Resolution Chromatography, 1985
- High-resolution PCB analysis: synthesis and chromatographic properties of all 209 PCB congenersEnvironmental Science & Technology, 1984
- Quantitative Determination of Specified Chlorobiphenyls in Fish with Capillary Gas Chromatography and its use for Monitoring and Tolerance PurposesInternational Journal of Environmental Analytical Chemistry, 1983
- Impregnation of silica gel with tetraalkylammonium salts in adsorption chromatography of neutral aromatic compoundsJournal of Chromatography A, 1976