Performance of a device to minimise radiation dose to the hands during radioactive syringe calibration
- 4 April 2003
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 30 (6) , 819-825
- https://doi.org/10.1007/s00259-003-1175-4
Abstract
The preparation of syringes for routine applications in nuclear medicine, and in particular the calibration procedure, is associated with high radiation exposure to the hands. To reduce this radiation burden, our group developed a modified calibration procedure based on a device that we refer to as the ActivoFix, which allows syringes to be drawn up inside the dose calibrator. This study investigated the performance of the new device as compared to the usual procedure of syringe calibration with regard to the absorbed radiation dose to the hands (fingertips and middle finger bases), the precision of the calibration procedure and the time required to calibrate syringes. Fourteen experienced nuclear medicine technologists drew up syringes from an initial eluate of 8.2 GBq using the conventional technique and the new calibration procedure. All technologists had to calibrate syringes with 50 MBq, 250 MBq and 650 MBq. This sequence was repeated four times using the conventional technique and then the new procedure. The equivalent dose to the hands was measured with thermoluminescent dosimeters. The exact amount of radioactivity in the syringe and the time needed for the calibration procedure were also recorded. The reduction in equivalent dose using the new device compared with the routine procedure ranged from 8.3- to 19.6-fold (mean 14.3-fold) for the fingers of the dominant hand and from 13.6- to 40.3-fold (mean 27-fold) for those of the non-dominant hand (total mean 21.3-fold). For small volumes, time could be saved with the ActivoFix, whereas for greater volumes time was lost. The device produced less variability in calibrating doses at 250 MBq and 650 MBq. Following the ALARA principle, the new device can be recommended for syringe calibration in nuclear medicine because the use of the ActivoFix-based procedure reduces finger dose by an average factor of 21, improves the precision of calibration and reduces the filling time for small volumes.Keywords
This publication has 10 references indexed in Scilit:
- Experimental determination of the anisotropy function and anisotropy factor for model 6711 I‐125 seedsMedical Physics, 2000
- Evaluation of Bicron NE MCP DXT-RAD Passive Extremity DosemeterRadiation Protection Dosimetry, 1999
- Dose from syringe procedures during technetium-99m radiopharmaceutical preparation.1998
- Comparison of personnel radiation dosimetry from myocardial perfusion scintigraphy: technetium-99m-sestamibi versus thallium-201.1993
- Radiation dose to the hands in nuclear medicineNuclear Medicine Communications, 1991
- External radiation doses to nuclear medicine technologists from procedures using 99mTc radiopharmaceuticals.1985
- External radiation exposure of personnel working with 99mTechnetiumEuropean Journal of Nuclear Medicine and Molecular Imaging, 1982
- Radiation doses to staff in a department of nuclear medicineThe British Journal of Radiology, 1976
- Use of thermoluminescent dosimeters for measurement of dose to the hands of nuclear medicine technicians.1972
- The question of radiation exposure to the hand from handling 99mTc.1969