Infected Dacron Mesorenal Portosystemic Shunt
- 1 January 1980
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 115 (1) , 81-82
- https://doi.org/10.1001/archsurg.1980.01380010067014
Abstract
• A serious septicemia developed in a patient two years after placement of a Dacron mesorenal shunt for bleeding esophageal varices. The source of the sepsis remained unknown for 13 months and was refractory to antibiotic therapy. Roentgenographic studies showed the shunt to be patent and without intralumenal thrombus. At operation, the shunt was being contaminated by a hole in the proximal jejunum and the patient has been cured of sepsis by removing the shunt. In contrast to the presentation of infected prosthesis used in the arterial system, infectious complications of prosthesis used in the portal systemic venous system occur without thrombosis of the shunt, aneurysm formation, or intraintestinal bleeding thus making operative evaluation the only means of diagnosis. (Arch Surg 115:81-82, 1980)This publication has 6 references indexed in Scilit:
- Common Bile Duct Obstruction Associated With a Dacron H-graft Portacaval ShuntArchives of Surgery, 1978
- Experience With Interposition Mesocaval Shunt for Management of Variceal BleedingArchives of Surgery, 1977
- PROSTHETIC MESOCAVAL SHUNTS IN PORTAL HYPERTENSIONThe Lancet, 1976
- Interposition grafting for portal hypertensionThe American Journal of Surgery, 1975
- Hemodynamics of the Interposition Mesocaval ShuntAnnals of Surgery, 1975