Clinical comparison between thallium-201 and Tc-99m-methoxy isobutyl isonitrile (hexamibi) myocardial perfusion imaging for detection of coronary artery disease
- 1 June 1989
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 15 (6) , 280-286
- https://doi.org/10.1007/bf00435466
Abstract
99mTc-hexamibi (methoxy isobutyl isonitrile) is a new 99mTc-hexakis analog that can be used as a myocardial perfusion imaging agent. The purposes of this study were to compare 99mTc-hexamibi to 201Tl-thallous chloride myocardial stress scintigraphy in patients referred for investigation of chest pain and to evaluate the sensitivity of 99mTc-hexamibi in detection of coronary artery disease. One hundred patients were prospectively studied with both 201Tl and 99mTc-hexamibi planar imaging. Sixty five patients had a current coronary angiography. There was a total of 97 significantly (≤70%) stenosed major coronary arteries. 99mTc-hexamibi (25 mCi) study was done within a week of the 201Tl scan with similar double products upon standard treadmil stress testing. Rest studies with 99mTc-hexamibi were obtained 24–48 h after the stress test using the same acquisition parameters and dose. Analysis was performed blind by three observers. The left ventricle was divided into five segments in each image. Analysis of 201Tl and 99mTc-hexamibi results in 1500 left ventricle segments showed an overall agreement in 1326/1500 (88.4%) segments. Correlation between the patient diagnosis on the 201Tl and 99mTc-hexamibi studies showed an agreement in 89 patients (89%). 201Tl revealed myocardial uptake defects in 526 segments, detecting 72 out of 97 (74.2%) significantly stenosed coronary arteries and 99mTc-hexamibi detected 513 segments corresponding to 68 (70.1%) stenosed arteries (no significant statistical difference). In conclusion, these results show a good correlation between 201Tl and 99mTc-hexamibi myocardial imaging in the detection of significant coronary artery disease.Keywords
This publication has 17 references indexed in Scilit:
- Myocardial Perfusion Imaging with a New Radiotracer, Technetium-99m-Hexamibi (Methoxy Isobutyl Isonitrile): Comparison with Thallium-201 ImagingClinical Nuclear Medicine, 1989
- Myocardial perfusion imaging with 99mTc-methoxy-isobutyl-isonitrile (MIBI): Comparison of short and long time intervals between rest and stress injectionsEuropean Journal of Nuclear Medicine and Molecular Imaging, 1988
- The Utilization of Technetium-99m CPI as a Myocardial Perfusion Imaging Agent in Exercise StudiesClinical Nuclear Medicine, 1987
- The utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humansEuropean Journal of Nuclear Medicine and Molecular Imaging, 1986
- The scintigraphic evaluation of myocardial infarction and regional ventricular performance using technetium-99m hexakis (t-butylisonitrile) technetium (I) (TBI): A new myocardial imaging agentEuropean Journal of Nuclear Medicine and Molecular Imaging, 1986
- UPTAKE OF HEXAKIS(T-BUTYLISONITRILE) TECHNETIUM (I) AND HEXAKIS- (ISOPROPYLISONITRILE) TECHNETIUM (I) BY NEONATAL RAT MYOCYTES AND HUMAN-ERYTHROCYTES1986
- EFFECT OF A DELAY IN COMMENCING IMAGING ON THE ABILITY TO DETECT TRANSIENT THALLIUM DEFECTS1985
- Biological studies of a new class of technetium complexes: the hexakis(alkylisonitrile)technetium(I) cationsInternational Journal of Nuclear Medicine and Biology, 1984
- Evaluation of 99mTc-dichloro bis (1,2-dimethylphosphino) ethane (99mTc-DMPE) for myocardial scintigraphy in manEuropean Journal of Nuclear Medicine and Molecular Imaging, 1983