A dosimetric intercomparison of electron beams in UK radiotherapy centres
- 1 December 1997
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 42 (12) , 2393-2409
- https://doi.org/10.1088/0031-9155/42/12/007
Abstract
A dosimetry intercomparison has been carried out for all 52 radiotherapy centres in the UK which possess electron treatment facilities. The intercomparison was carried out on one treatment unit in each centre and for three energies across the range of available energies. The position of the depth of maximum dose for a standard field size was independently determined and a subsequent beam calibration made. The factor to convert the reading on a calibrated ionization chamber to absorbed dose in an electron beam is energy dependent, and hence to carry out an independent calibration measurement also requires the beam energy to be determined. In addition a quantitative measure of the difference in the calibration chains between the intercomparison equipment and the host department's field instrument was carried out. In order to provide a follow-up to the initial IPSM national photon intercomparison, a photon beam calibration was measured in one photon beam in each centre. For 156 electron beam measurements, a mean ratio of intercomparison measured dose to locally measured dose of 0.994 was obtained with a standard deviation of 1.8%. For the 52 photon beam measurements, a mean ratio of intercomparison measured dose to locally measured dose of 1.003 was obtained with a standard deviation of 1.0%.Keywords
This publication has 23 references indexed in Scilit:
- The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al - 4 mm Cu HVL; 10 - 300 kV generating potential)Physics in Medicine & Biology, 1996
- The development of an interdepartmental audit as part of a physics quality assurance programme for external beam therapyThe British Journal of Radiology, 1994
- Correction factors for calibration of plane-parallel ionization chambers with a60Co gamma-ray beamPhysics in Medicine & Biology, 1993
- Addendum to the code of practice for electron beam dosimetry in radiotherapy (1985): interim additional recommendationsPhysics in Medicine & Biology, 1992
- Code of Practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration servicePhysics in Medicine & Biology, 1990
- Dose intercomparison at the radiotherapy centres in The Netherlands. 1. Photon beams under reference conditions and for prostatic cancer treatmentRadiotherapy and Oncology, 1987
- Quality assurance control in the EORTC cooperative group ofradiotherapyRadiotherapy and Oncology, 1986
- Dosimetric Precision Requirements in Radiation TherapyActa Radiologica: Oncology, 1984
- Revised Code of Practice for the dosimetry of 2 to 35 MV x-ray, and of caesium-137 and cobalt-60 gamma-ray beamsPhysics in Medicine & Biology, 1983
- Dosimetric Intercomparison at the Scandinavian Radiation Therapy Centres I. Absorbed Dose IntercomparisonActa Radiologica: Oncology, 1982