Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac Catheterization
Top Cited Papers
- 4 January 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 111 (1) , 83-89
- https://doi.org/10.1161/01.cir.0000151098.52656.3a
Abstract
Background— Because of the higher radiosensitivity of infants and children compared with adults, there is a need to evaluate the doses delivered to pediatric patients who undergo interventional cardiac procedures. However, knowledge of the effective dose in pediatric interventional cardiology is very limited. Methods and Results— For an accurate risk estimation, a patient-specific Monte Carlo simulation of the effective dose was set up in 60 patients with congenital heart disease who underwent diagnostic (n=28) or therapeutic (n=32) cardiac catheterization procedures. The dose-saving effect of using extra copper filtration in the x-ray beam was also investigated. For diagnostic cardiac catheterizations, a median effective dose of 4.6 mSv was found. Therapeutic procedures resulted in a higher median effective dose of 6.0 mSv because of the prolonged use of fluoroscopy. The overall effect of inserting extra copper filtration into the x-ray beam was a total effective dose reduction of 18% with no detrimental effect on image quality. An excellent correlation between the dose-area product and effective patient dose was found ( r =0.95). Hence, dose-area product is suitable for online estimation of the effective dose with good accuracy. With all procedures included, the resulting median lifetime risk for stochastic effects was 0.08%. Conclusions— Because of the high radiation exposure, it is important to monitor patient dose by dose-area product instrumentation and to use additional beam filtration to keep the effective dose as low as possible in view of the sensitivity of the pediatric patients.Keywords
This publication has 16 references indexed in Scilit:
- Correlation of patient skin doses in cardiac interventional radiology with dose-area product.The British Journal of Radiology, 2000
- Effective doses to patients from paediatric cardiac catheterization.The British Journal of Radiology, 2000
- Estimating the effective dose to children undergoing heart investigations--a phantom study.The British Journal of Radiology, 1999
- Dosimetric and radiation protection considerations based on some cases of patient skin injuries in interventional cardiology.The British Journal of Radiology, 1998
- Reduced Radiation During Cardiac Catheterization of Infants Using Acquisition Zoom TechnologyThe American Journal of Cardiology, 1997
- Patient dosimetry in interventional radiology using slow films.The British Journal of Radiology, 1997
- Radiation exposure to children during cardiac catheterization.The British Journal of Radiology, 1997
- Radiation exposure and efficacy of exposure-reduction techniques during cardiac catheterization in children.American Journal of Roentgenology, 1994
- Patient radiation exposure during pediatric cardiac catheterizationCardioVascular and Interventional Radiology, 1983
- Radiation exposure to the paediatric patient from cardiac catheterization and angiocardiographyThe British Journal of Radiology, 1980