Simultaneous on-line preconcentration and determination of Pt, Rh and Pd in urine, serum and road dust by flow injection combined with inductively coupled plasma time-of-flight mass spectrometry
- 27 June 2003
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (9) , 1019-1025
- https://doi.org/10.1039/b302441e
Abstract
In this work, ICP-time of flight (TOF)-MS with ultrasonic nebulisation (USN) was combined on-line with a flow injection (FI) system for the determination of Pt, Rh and Pd in biological fluids (urine and blood serum) and road dust. Simultaneous and selective preconcentration of the 3 analytes was performed by sorption of their complexes formed on-line with diethylthiourea (DET) on the inner walls of a PTFE knotted reactor (KR), in a wide range of sample acidity (0.1–0.5 M HNO3 for Pd and Rh and 0.05–0.2 M HNO3 for Pt). A quantitative elution was achieved using 500 µl methanol acidified with 1% HNO3 . The detection limits obtained were 0.54, 2.12 and 0.36 ng l−1 for Pt, Rh and Pd, respectively, and the relative standard deviation RSD (for 50 ng l−1 of Pt, Rh and 25 ng l−1 of Pd, n = 6) was ≤ 3%. Using a preconcentration time of 120 s and a sample flow rate of 5 ml min−1, enrichment factors of 55, 5 and 2 for Pd, Pt and Rh, respectively, were obtained in comparison with direct determination by ICP-MS without preconcentration. Special attention was paid to the study of the adverse effects of potentially interfering species present in the matrix (Cd, Cu, Pb, Sr, Fe, Y, Zn, Ni, Rb, Mn and Mo) on the preconcentration and the mass-spectrometric determination of the analytes. The accuracy of the method was demonstrated by the analysis of urine, blood serum and road dust certified reference materials. The method was applied to urine and serum samples of healthy subjects. The concentrations of Pt, Rh and Pd determined in these samples were comparable to reported values.Keywords
This publication has 34 references indexed in Scilit:
- Microwave-assisted digestion procedure for the determination of palladium in road dustAnalytica Chimica Acta, 2002
- Comparative study of 8-hydroxyquinoline derivatives as chelating reagents for flow-injection preconcentration of cobalt in a knotted reactorAnalytica Chimica Acta, 2001
- Determination of Pd, Pt and Rh in airborne particulate and road dust by high-resolution ICP-MS: a preliminary investigation of the emission from automotive catalysts in the urban area of RomeJournal of Analytical Atomic Spectrometry, 2000
- Critical assessment of platinum group element determination in road and urban river sediments using ultrasonic nebulisation and high resolution ICP-MSJournal of Analytical Atomic Spectrometry, 2000
- Ultratrace determination of cobalt in natural waters by electrothermal atomic absorption spectrometry using flow-injection on-line sorption preconcentration in a knotted reactor precoated with 1-phenyl-3-methyl-benzoylpyrazol-5-oneJournal of Analytical Atomic Spectrometry, 2000
- Control of interferences in the determination of Pt, Pd and Rh in airborne particulate matter by inductively coupled plasma mass spectrometryPublished by Elsevier ,1999
- Analytical problems in the determination of platinum-group metals in urine by quadrupole and magnetic sector field inductively coupled plasma mass spectrometryPublished by Elsevier ,1998
- Determination of Platinum at Trace Levels in Environmental and Biological MaterialsEnvironmental Science & Technology, 1997
- Selective determination of palladium by on-line column preconcentration and graphite furnace atomic absorption spectrometryAnalytica Chimica Acta, 1996
- Preconcentration of palladium, platinum and rhodium by on-line sorbent extraction for graphite furnace atomic absorption spectrometry and inductively coupled plasma atomic emission spectrometryAnalytica Chimica Acta, 1993