Comparison of a Modified Double-Lumen Endotracheal Tube with a Single-Lumen Tube with Enclosed Bronchial Blocker
- 1 December 1996
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 83 (6) , 1268-1272
- https://doi.org/10.1213/00000539-199612000-00024
Abstract
Ocedures were randomly assigned to one of two groups. Twenty patients received a left-side modified BronchoCath[R] double-lumen tube (DLT), and 20 received a Univent[R] tube with a bronchial blocker. The following were studied: 1) time required to position each tube until satisfactory, placement was achieved; 2) number of times that the fiberoptic bronchoscope was required; 3) frequency of malpositions after initial placement with fiberoptic bronchoscopy; 4) time required until lung collapse; 5) surgical exposure ranked by surgeons blinded to type of tube used; and 6) cost of tubes per case. No differences were found in: 1) time required to position each tube (DLT 6.2 +/- 3.1 versus Univent[R] 5.4 +/- 4.5 min [mean +/- SD]); 2) number of bronchoscopies per patient (DLT median 2, range 1-3 versus Univent[R] median 3, range 2-5); or 3) time to lung collapse (DLT 7.1 +/- 5.4 versus Univent[R] 12.3 +/- 10.5 min). The frequency of malposition was significantly lower for the DLT [5] compared to the Univent[R] [15] (P < 0.003). Blinded evaluations by surgeons indicated that 18/20 DLT provided excellent exposure compared to 15/20 for the Univent[R] group (P = not significant). We conclude that in spite of the greater frequency of malposition seen with the Univent[R], once position was corrected adequate surgical exposure was provided. In the Univent[R] group the incidence of malposition and cost involved were both sufficiently greater that we cannot find cost/efficacy justification for routine use of this device. (Anesth Analg 1996;83:1268-72)...Keywords
This publication has 15 references indexed in Scilit:
- Placement of left double-lumen endobronchial tubes with or without a styletCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1996
- Nasal Intubation and One-Lung VentilationAnesthesiology, 1996
- Univent tube: A useful device in patients with difficult airwaysJournal of Cardiothoracic and Vascular Anesthesia, 1995
- Modified bronchocath double-lumen tubeJournal of Cardiothoracic and Vascular Anesthesia, 1995
- The position of a Double-Lumen Tube should be routinely determined by Fiberoptic BronchoscopyJournal of Cardiothoracic and Vascular Anesthesia, 1993
- Con: The univent tube is not the best method of providing one-lung ventilationJournal of Cardiothoracic and Vascular Anesthesia, 1993
- Pro: One-lung ventilation is best accomplished with the univent endotracheal tubeJournal of Cardiothoracic and Vascular Anesthesia, 1993
- The utility of a double-lumen tube for one-lung ventilation in a variety of noncardiac thoracic surgical proceduresJournal of Cardiothoracic and Vascular Anesthesia, 1992
- Right upper lobe obstruction with right-sided double-lumen endobronchial tubes: A comparison of two tube typesJournal of Cardiothoracic Anesthesia, 1988
- Margin of Safety in Positioning Modern Double-lumen Endotracheal TubesAnesthesiology, 1987