Specimen heat fluxes for bench‐scale heat release rate testing
- 1 November 1995
- journal article
- research article
- Published by Wiley in Fire and Materials
- Vol. 19 (6) , 243-252
- https://doi.org/10.1002/fam.810190602
Abstract
When a specimen is testd for its heat release rate (HRR) behaviour using a bench‐scale such as ISO 5660 or equivalent, one very important test condition is not pre‐standaridized and must be set: the heat flux to be imposed on the specimen by the heater. The heat flux cannot be ligitimately standardized, since the value appropriately to be used will differ according to purpose or application. The present paper sets forth the considerations which should govern the correct choice of heat flux. A discussion is given of minimum ignitiability level; statistical variability at low heat fluxes; the ranges of heat fluxes associated with small actual ignition sources; the heat fluxes associated with fires away from the ignition sources, all the way up to fully‐involved room fires; the application of the product; and the needs associated with mathematical modeling of room fires. Correlational approaches are also illustrated and contrasted to physics‐based ones. Finally, the empirical nature of the present situation is emphasized. Judged from first principles, it would appear that successful prediction of room fire results from bench‐scale test data would require both the testing at a large number of different heat fluxes and the use of algorithms to permit time‐dependent interpolation. Such algorithms have been proposed; however, some very successful predictions are noted with much simpler techniques.Keywords
This publication has 21 references indexed in Scilit:
- Bench-Scale Predictions of Mattress and Upholstered Chair Fires: Similarities and DifferencesPublished by ASTM International ,1994
- Survey of fire testing of electrical cablesFire and Materials, 1992
- Full‐scale/Bench‐Scale correlations of wall and ceiling liningsFire and Materials, 1992
- Comparison of the Fire Performance of Various Upholstered Furniture Composite Combinations (Fabric/Foam) in Two Rate of Heat Release Calorimeters: Cone and Ohio State University InstrumentsJournal of Fire Sciences, 1991
- Fire exposure to exterior walls and flame spread on combustible claddingFire Technology, 1990
- Fluxmeter measurements at low thermal levels: Some problemsFire Technology, 1985
- The historical basis of fire resistance testing — Part IIFire Technology, 1978
- The historical basis of fire resistance testing — Part IFire Technology, 1978
- The Importance of Externally Imposed Heat Flux on the Burning Behavior of MaterialsJournal of Cellular Plastics, 1978
- Throne — continued from page 24Journal of Cellular Plastics, 1978