Resistance of microorganisms to disinfection in dental and medical devices
- 1 September 1995
- journal article
- Published by Springer Nature in Nature Medicine
- Vol. 1 (9) , 956-958
- https://doi.org/10.1038/nm0995-956
Abstract
The U.S. Centers for Disease Control and Prevention (CDC) recommends that only heat sterilization be used for all reusable devices entering the oral cavity1. However, chemical disinfection is still employed for reprocessing dental devices in many areas of the world. In an analysis of a Florida dental practice responsible for nosocomial human immunodeficiency virus (HIV) transmissions, the possible role of contaminated devices was deemed unlikely in part because they were subjected to high–level disinfection with 2% glutaraldehyde2. Disease transmissions have, however, been documented for endoscopes used in diagnostic and surgical procedures even after this treatment3. In some dental devices, lubricants mix with potentially infectious patient materials, and organic debris has been observed in endoscopes after cleaning4–6. We have investigated whether lubricants can render high–level chemical disinfection procedures ineffective and have addressed the role that some common devices may play in disease transmission. We report here that HIV in whole–blood samples and Pseudomonas aeruginosa in blood and plasma survived high–level disinfection when entrapped in lubricants used in dental handpieces and endoscopes. We also found that lubricated dental devices used to clean and polish teeth (prophylaxis angles) have the potential to transfer sufficient amounts of blood to infect human lymphocyte cultures with HIV. These results emphasize the need to subject reusable dental devices to a heat–sterilization protocol that penetrates the lubricant7.Keywords
This publication has 7 references indexed in Scilit:
- Lack of HIV Transmission in a Dental PracticeAnnals of Internal Medicine, 1995
- Transmission of Infection by Gastrointestinal Endoscopy and BronchoscopyAnnals of Internal Medicine, 1993
- Lack of Evidence for Patient-to-Patient Transmission of HIV in a Dental PracticeThe Journal of the American Dental Association, 1993
- Significant factors in the disinfection and sterilization of flexible endoscopesAmerican Journal of Infection Control, 1992
- Cross-contamination potential with dental equipmentThe Lancet, 1992
- Reducing Occupational Risk of HIV InfectionHospital Practice, 1991
- Strategies for Disinfection and Sterilization of Endoscopes: The Gap between Basic Principles and Actual PracticeInfection Control & Hospital Epidemiology, 1991