Automation of the Limulus amoebocyte lysate test by using the Abbott MS-2 microbiology system
- 1 June 1981
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 41 (6) , 1316-1320
- https://doi.org/10.1128/aem.41.6.1316-1320.1981
Abstract
A rapid, automated method for the performance of the Limulus amoebocyte lysate endotoxin assay has been developed by using the Abbott MS-2 Microbiology System. This instrument automatically determines sequential changes in the optical density of up to 176 samples at 1- or 5-min increments during a 1-h assay period. Graphic representation of optical density changes can be viewed on a cathode-ray tube or reproduced by using a hard-copy printer. Limulus amoebocyte lysate preparations that were obtained from different commercial producers and that had similar endotoxin sensitivities by the conventional gelation method varied somewhat in reactivity when determinations were based upon rate changes in optical density. Lysates from Associates of Cape Cod, Difco Laboratories, and M. A. Bioproducts were the most readily adaptable to the MS-2 System. Use of the MS-2 system increased the sensitivity of these preparations from 60- to 250-fold, and as little as 1 pg/ml was detected. Adaptation of the MS-2 instrument for this purpose provides an objective, reproducible, automated method for the performance of Limulus amoebocyte lysate tests on a variety of fluids.This publication has 22 references indexed in Scilit:
- Rapid presumptive diagnosis of gonococcal cervitis by the limulus lysate assayAmerican Journal of Obstetrics and Gynecology, 1980
- Rapid presumptive diagnosis of gonococcal urethritis in men by the limulus lysate test.Sexually Transmitted Infections, 1979
- Limulus Lysate Assay for Early Detection of Certain Gram-Negative Corneal InfectionsArchives of Ophthalmology (1950), 1979
- Quantitative Limulus lysate assay for endotoxin activity: Aggregation of radioiodinated coagulogen monomersAnalytical Biochemistry, 1978
- Diagnostic Limulus Lysate Assay For Endophthalmitis and KeratitisArchives of Ophthalmology (1950), 1978
- Lack of Clinical Usefulness of the Limulus Test in the Diagnosis of EndotoxemiaNew England Journal of Medicine, 1975
- Comparative Evaluation of the Limulus Assay and the Direct Gram Stain for Detection of Significant BacteriuriaAmerican Journal of Clinical Pathology, 1975
- Slide Test as a Micromethod of a Modified Limulus Endotoxin TestJournal of Pharmaceutical Sciences, 1974
- Rapid Detection of Gram-Negative Bacterial Meningitis by the Limulus Lysate TestNew England Journal of Medicine, 1973
- Gram-Negative Sepsis: Detection of Endotoxemia with the Limulus TestAnnals of Internal Medicine, 1972