Effect of constrained posterior screw and rod systems for primary stability: Biomechanical in vitro comparison of various instrumentations in a single-level corpectomy model
Open Access
- 10 July 2004
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 14 (4) , 372-380
- https://doi.org/10.1007/s00586-004-0763-8
Abstract
Cervical corpectomy is a frequently used technique for a wide variety of spinal disorders. The most commonly used approach is anterior, either with or without plating. The results for single-level corpectomy are better than in multilevel procedures. Nevertheless, hardware- or graft-related complications are observed. In the past, constrained implant systems were developed and showed encouraging stability, especially for posterior screw and rod systems in the lumbar spine. In the cervical spine, few reports about the primary stability of constrained systems exist. Therefore, in the present study we evaluated the primary stability of posterior screw and rod systems, constrained and non-constrained, in comparison with anterior plating and circumferential instrumentations in a non-destructive set-up, by loading six human cadaver cervical spines with pure moments in a spine tester. Range of motion and neutral zone were measured for lateral bending, flexion/extension and axial rotation. The testing sequence consisted of: (1) stable testing; (2) testing after destabilization and cage insertion; (3a) additional non-constrained screw and rod system with lateral mass screws, (3b) with pedicle screws instead of lateral mass screws; (4a) constrained screw and rod system with lateral mass screws, (4b) with pedicle screws instead of lateral mass screws; (5) 360 degrees set-up; (6) anterior plate. The stability of the anterior plate was comparable to that of the non-constrained system, except for lateral bending. The primary stability of the non-constrained system could be enhanced by the use of pedicle screws, in contrast to the constrained system, for which a higher primary stability was still found in axial rotation and flexion/extension. For the constrained system, the achievable higher stability could obviate the need to use pedicle screws in low instabilities. Another benefit could be fewer hardware-related complications, higher fusion rate, larger range of instabilities to be treated by one implant system, less restrictive postoperative treatment and possibly better clinical outcome. From a biomechanical standpoint, in regard to primary stability the constrained systems, therefore, seem to be beneficial. Whether this leads to differences in clinical outcome has to be evaluated in clinical trials.Keywords
This publication has 61 references indexed in Scilit:
- Posterior Cervical Arthrodesis and Stabilization: An Early Report Using a Novel Lateral Mass Screw and Rod TechniqueNeurosurgery, 1999
- Hardware Failure in an Unconstrained Lumbar Pedicle Screw SystemSpine, 1999
- Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implantsEuropean Spine Journal, 1998
- Effect of Spinal Construct Stiffness on Short Segment Fusion Mass IncorporationSpine, 1995
- Anterior cervical fixation with the titanium locking screw-plate: A preliminary reportSurgical Neurology, 1994
- Reduction of High-Grade Slips (Grades Hi—V) with VSP® InstrumentationSpine, 1991
- Roentgenographic and biomechanical analysis of lumbar fusions: A canine modelJournal of Orthopaedic Research, 1989
- 1989 Volvo Award in Basic Science: Device-Related Osteoporosis with Spinal InstrumentationSpine, 1989
- Accelerated Degeneration of the Segment Adjacent to a Lumbar FusionSpine, 1988
- Cervical Stabilization by Plate and Bone FusionSpine, 1988