Reflected ultrasound as a diagnostic instrument in study of mitral valve disease.
Open Access
- 1 September 1967
- Vol. 29 (5) , 788-800
- https://doi.org/10.1136/hrt.29.5.788
Abstract
Analysis of mitral valve motion in 200 patients revealed 75 normal, 44 with predominant mitral stenosis, and 81 with mixed mitral and aortic disease. Comparison with results from catheterization data, cine-angiography, surgery, apex cardiography, and phonocardiography was made. In patients with mitral stenosis, an ultrasound diastolic slope of less than 25 mm/sec. correlated well with a calculated mitral valve area of under 1 sq. cm, moderately severe stenosis on cineangiography, and a finger tip orifice at operation. Lesser degrees of stenosis were associated with slopes up to 45 mm/sec. No patient with the murmur of mitral stenosis with or without mitral insufficiency exhibited a slope of greater than 45 mm/sec. Normal mitral valve motion was accompanied by slopes in excess of 65 mm/sec. Amplitude of excursion generally diminished directly with the slope though with a wide scatter. A nearly normal amplitude was found in several patients with advanced mitral stenosis in whom the chordae apparatus was nearly intact. In mitral insufficiency, the diastolic slope varied from that seen with severe restriction (17 mm/sec.) to that seen with normal valves (over 65 mm/sec). The determining factor appeared to be degree of fibrosis, calcification, and chordae fusion present. Flail valves with high mobility were less likely to be the result of rheumatic involvement. In the presence of clinical signs of mitral insufficiency, a slope of less than 35 mm/sec, suggests severely damaged leaflets with fibrosis, with or without calcification, and some narrowing of the orifice with little of the normal ability to close. Slopes intermediate between 35 and 70 mm/sec, indicate lesser degrees of fixation.This publication has 19 references indexed in Scilit:
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IPublished by Elsevier ,2004
- Clinical application of ultrasound in the analysis of prosthetic ball valve function∗The American Journal of Cardiology, 1967
- Echocardiography. Clinical application in mitral stenosisJAMA, 1966
- DYNAMICS OF THE STARR-EDWARDS BALL VALVE PROSTHESISThe Lancet Healthy Longevity, 1965
- The apex cardiogram and its relationship to haemodynamic events within the left heart.Heart, 1965
- Diagnostic Value of Ultrasonic CardiographyThe British Journal of Radiology, 1964
- Reflected Ultrasound in the Assessment of Mitral Valve DiseaseCirculation, 1963
- ULTRASONICS IN THE DIAGNOSIS OF INTRACRANIAL SPACE-OCCUPYING LESIONSThe Lancet, 1961
- Diastolic movements of the precordium in mitral stenosis and regurgitationAmerican Heart Journal, 1960
- THE ASSESSMENT OF MITRAL STENOSIS BY PHONOCARDIOGRAPHYHeart, 1954