A multi-centre evaluation of the intra-assay and inter-assay variation of commercial and in-house anti-cardiolipin antibody assays
- 1 April 2004
- Vol. 36 (2) , 182-192
- https://doi.org/10.1080/00313020410001672037
Abstract
To assess the intra-assay (intra-run) and inter-assay (inter-run) variation of commercial and in-house IgG and IgM anti-cardiolipin antibody (aCL) assays/kits, and to determine an appropriate maximum value for inclusion in consensus guidelines. Frozen aliquots of two patient specimens and one commercial control were sent to nine laboratories for the evaluation of eight commercial kits and one in-house assay. Intra-assay and inter-assay evaluations were performed with all three samples for IgG aCL, and one patient specimen for IgM aCL. The IgG and IgM aCL values varied considerably between the nine assays/kits. The majority of assays/kits demonstrated less than 20% intra-assay and inter-assay variation, with lower intra-assay and inter-assay variation observed with the commercial control. Single calibrator assays were not consistently associated with higher interassay variation than multi-point calibrator assays. An inter-assay coefficient of variation of 20% was determined to be an appropriate maximum value for inclusion in the Australasian aCL Working Party consensus guidelines. Improved standardisation between different assay/kits is still required.Keywords
This publication has 15 references indexed in Scilit:
- Consensus guidelines on anti-cardiolipin antibody testing and reportingPathology, 2004
- Lupus anticoagulants are stronger risk factors for thrombosis than anticardiolipin antibodies in the antiphospholipid syndrome: a systematic review of the literatureBlood, 2003
- Assessing the Usefulness of Anticardiolipin Antibody AssaysAmerican Journal of Clinical Pathology, 2002
- Revisiting the anticardiolipin test and its standardizationLupus, 2002
- Inter‐assay variation in antiphospholipid antibody testingBJOG: An International Journal of Obstetrics and Gynaecology, 2002
- Persistent Problems with Standardization of Immunoassays for Anti-Cardiolipin AntibodiesThrombosis and Haemostasis, 2001
- Anticardiolipin Antibody Assay: a Methodological Analysis for a better Consensus in Routine DeterminationsThrombosis and Haemostasis, 2001
- Clinical utility of anticardiolipin antibody assays: high inter-laboratory variation and limited consensus by participants of external quality assurance programs signals a cautious approachPathology, 1999
- Multicenter Evaluation of Nine Commercial Kits for the Quantitation of Anticardiolipin AntibodiesThrombosis and Haemostasis, 1995
- Interlaboratory inconsistencies in detection of anticardiolipin antibodiesThe Lancet, 1990