Determination of ceftriaxone in biological material by differential-pulse adsorptive stripping voltammetry
- 1 January 1990
- journal article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 115 (6) , 873-874
- https://doi.org/10.1039/an9901500873
Abstract
Differential-pulse adsorptive stripping voltammetry was used to determine sub-micromolar concentrations of ceftriaxone in plasma. A hanging mercury drop electrode was chosen as the working electrode. A simple clean-up procedure was developed in which ceftriaxone was extracted from blood plasma with the non-ionic resin Amberlite XAD-2 and eluted with methanol. The recovery from plasma was 97.6% using a 1.52 × 10–4 M stock ceftriaxone solution. The method was applied to caesarian cases, and total ceftriaxone levels were measured in the maternal and umbilical cord blood. The amount of ceftriaxone transmitted to the baby on administration of the drug to the mother before the caesarian operation was found to be in the range 0.067–0.17%.Keywords
This publication has 0 references indexed in Scilit: