Design and implementation of a sensitive high-resolution nonlinear spectral imaging microscope
- 1 January 2008
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 13 (4) , 044019-044019-11
- https://doi.org/10.1117/1.2953180
Abstract
Live tissue nonlinear microscopy based on multiphoton autofluorescence and second harmonic emission originating from endogenous fluorophores and noncentrosymmetric-structured proteins is rapidly gaining interest in biomedical applications. The advantage of this technique includes high imaging penetration depth and minimal phototoxic effects on tissues. Because fluorescent dyes are not used, discrimination between different components within the tissue is challenging. We have developed a nonlinear spectral imaging microscope based on a home-built multiphoton microscope, a prism spectrograph, and a high-sensitivity CCD camera for detection. The sensitivity of the microscope was optimized for autofluorescence and second harmonic imaging over a broad wavelength range. Importantly, the spectrograph lacks an entrance aperture; this improves the detection efficiency at deeper lying layers in the specimen. Application to the imaging of ex vivo and in vivo mouse skin tissues showed clear differences in spectral emission between skin tissue layers as well as biochemically different tissue components. Acceptable spectral images could be recorded up to an imaging depth of .
Keywords
This publication has 47 references indexed in Scilit:
- Spectrally Resolved Multiphoton Imaging of In Vivo and Excised Mouse Skin TissuesBiophysical Journal, 2007
- The Nikon C1si combines high spectral resolution, high sensitivity, and high acquisition speedCytometry Part A, 2006
- In vivo nonlinear spectral imaging in mouse skinOptics Express, 2006
- The big pictureNature, 2005
- Two-photon 3-D mapping of ex vivo human skin endogenous fluorescence species based on fluorescence emission spectraJournal of Biomedical Optics, 2005
- Application of spectral imaging microscopy in cytomics and fluorescence resonance energy transfer (FRET) analysisCytometry Part A, 2004
- Spectral imaging and linear un‐mixing enables improved FRET efficiency with a novel GFP2–YFP FRET pairFEBS Letters, 2002
- Resolution of multiple green fluorescent protein color variants and dyes using two-photon microscopy and imaging spectroscopyJournal of Biomedical Optics, 2001
- Multispectral Imaging Autofluorescence Microscopy for the Analysis of Lymph-Node TissuesPhotochemistry and Photobiology, 2000
- AOTF microscope for imaging with increased speed and spectral versatilityBiophysical Journal, 1997