Perceptions of Indoor Air Quality Associated with Ventilation System Types in Elementary Schools
- 1 October 2001
- journal article
- research article
- Published by Taylor & Francis in Applied Occupational and Environmental Hygiene
- Vol. 16 (10) , 952-960
- https://doi.org/10.1080/104732201300367209
Abstract
With the increased utilization of school buildings on a year-round basis, school indoor air quality has become a national concern. The purpose of this study was to evaluate possible associations between ventilation system type and occupant perception of indoor air quality. Staff (n=403)from 12 schools completed a self-administered questionnaire. Carbon dioxide (CO 2 ) levels, air exchange rates, and particle counts were also measured for each school. Schools with unit ventilator (UV) systems had the lowest mean CO 2 level at 637 ppm, followed by the variable air volume (VAV) systems with 664 ppm, and constant volume (CV) systems with a mean of 703 ppm. Schools with UV systems had the lowest mean air exchange rate at 2.67 air changes per hour (ACH), followed by the VAV system type at 2.80 ACH and the CV system type at 4.61 ACH. Indoor versus outdoor particle ratios were calculated for each ventilation system type. Particles with aerodynamic diameters ranging from 0.1-1.0 w m had a geometric mean ratio ranging from 0.38 to 0.68; particles with aerodynamic diameters ranging from 1-3 w m had ratios ranging from 1.39 to 5.47, and particles with aerodynamic diameters greater than 3 w m had ratios ranging from 3.20 to 14.76. Schools using VAV systems had a significantly lower prevalence of red and watery eyes while schools with UV systems had an elevated prevalence of nasal congestion, sore throat, headache, and dustiness complaints. This increased prevalence of complaints in buildings with UV systems may be due to the increased particulate levels.Keywords
This publication has 27 references indexed in Scilit:
- Real-Time Monitoring of Particles, PAH, and CO in an Occupied TownhouseApplied Occupational and Environmental Hygiene, 2000
- The Indoor Environment of a Modern Museum Building, The Sainsbury Centre for Visual Arts, Norwich, UKIndoor Air, 1999
- Airborne house dust particles and diesel exhaust particles as allergen carriersClinical and Experimental Allergy, 1998
- Particulate matter less than 10 μm (PM10) and fine particles less than 2.5 μm (PM2.5): relationships between indoor, outdoor and personal concentrationsScience of The Total Environment, 1997
- Occupant Generated Carbon Dioxide as a Measure of Dilution Ventilation EfficiencyAihaj Journal, 1996
- Case Studies: Investigations Into the Indoor Environmental Quality of a School: A Two-Year Educational ExperienceApplied Occupational and Environmental Hygiene, 1996
- Indoor Air Quality Investigation: Experience with a Questionnaire Survey InstrumentApplied Occupational and Environmental Hygiene, 1992
- Indoor Exposures to Fine Aerosols and Acid GasesEnvironmental Health Perspectives, 1991
- The sick building syndrome: prevalence studies.BMJ, 1984
- The Analysis of Residuals in Cross-Classified TablesPublished by JSTOR ,1973