Report on the dosimetry of a new design brachytherapy source
- 7 September 1999
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 26 (9) , 1925-1931
- https://doi.org/10.1118/1.598737
Abstract
Dosimetric measurements were performed to characterize a new 125I source that is a variant design of an existing source, designated as MED3631-A/S, and that has application in interstitial brachytherapy. The new source, designated as MED3631-A/M, has centralized radio-opaque markers. In the original MED3631-A/S source, the radio-opaque markers are separated. Thermoluminescent dosimeters were placed in phantom to measure transverse axis and angular dose profiles over a range of distances from 0.5 to 7 cm. The data were analyzed in terms of parameters recommended by AAPM Task Group No. 43. Tabular data evaluated in liquid water are provided for the dose-rate constant, lambda, radial dose function, g(r), the anisotropy function, F(r,theta), the anisotropy factor, phi(an)(r), the point-source approximation anisotropy constant, phi(an). The dose-rate constant was determined by an absolute method using a Cobalt-60 reference and by relative measurements using calibrated 125I source(s). Values of the dose-rate constant are provided for both the 1985 and 1999 NIST air-kerma strength standards. The new source is comparable to both the MED3631-A/S and the model 6702 125I source designs, demonstrating equivalent radial dose function, g(r). Differences in the value of the dose-rate constant, lambda, and the anisotropy of the dose distributions in phantom are discussed in light of the improved isotropy of the new design, the MED3631-A/M source, and the uncertainty involved in the dose measurement using a Cobalt-60 reference.Keywords
This publication has 25 references indexed in Scilit:
- Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sourcesMedical Physics, 1998
- Evaluation of a new brachytherapy iodine‐125 source by AAPM TG43 formalismMedical Physics, 1998
- Clinical Impact of Implementing the Recommendations of AAPM Task Group 43 on Permanent Prostate Brachytherapy Using 125IInternational Journal of Radiation Oncology*Biology*Physics, 1998
- One-dimensional scatter-subtraction method for brachytherapy dose calculation near bounded heterogeneitiesMedical Physics, 1993
- Dose rate determination for 125I seedsMedical Physics, 1990
- Dose distributions of model 6702 I-125 seeds in waterInternational Journal of Radiation Oncology*Biology*Physics, 1987
- Exposure Standardization of Iodine-125 Seeds Used for BrachytherapyJournal of Research of the National Bureau of Standards, 1984
- Physical dosimetry of 125I seeds of a new design for interstitial implantInternational Journal of Radiation Oncology*Biology*Physics, 1983
- Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100Atomic Data and Nuclear Data Tables, 1970