Separation of reduced and oxidized glutathione by micellar electrokinetic capillary chromatography
- 1 July 1993
- journal article
- Published by Wiley in Biomedical Chromatography
- Vol. 7 (4) , 220-226
- https://doi.org/10.1002/bmc.1130070410
Abstract
The separation of reduced and oxidized glutathione at an absolute sensitivity of about 100 pg by micellar electrokinetic capillary chromatography without derivatization is described. The time required for the separation is less than 10 min (the time between two following injections is about 15 min). The separation is characterized by high efficiency and good reliability. A partition mechanism is responsible for the high resolution observed. The method was utilized for the analysis of commercial preparations of glutathione and a good agreement with the expected results was obtained; the oxidation of the commercial glutathione in solution was easily analysed.Keywords
This publication has 10 references indexed in Scilit:
- Separation of reduced and oxidized glutathione in a pharmaceutical preparation by ion-interaction reversed-phase HPLCJournal of Pharmaceutical and Biomedical Analysis, 1992
- Problems of quantitative injection in capillary zone electrophoresisAnalytical Chemistry, 1992
- Peptide mapping through the coupling of capillary electrophoresis and high-performance liquid chromatography: map prediction of the tryptic digest of myoglobinJournal of Chromatography B: Biomedical Sciences and Applications, 1991
- Application of high-performance thin-layer chromatography—fluorescence densitometry to the simultaneous determination of reduced and oxidized glutathioneJournal of Chromatography A, 1990
- Glutathione reductase inhibitors as potential antimalarial drugsBiochemical Pharmacology, 1988
- Simultaneous determination of glutathione, glutathione disulphide, paracetamol and its sulphur containing metabolites using HPLC and electrochemical detection with on-line generated bromineJournal of Pharmaceutical and Biomedical Analysis, 1988
- Measurement of Tissue Sulfhydryls and Disulfides in Tissue Protein and Nonprotein Fractions by High Performance Liquid Chromatography Using Electrochemical DetectionJournal of Liquid Chromatography, 1987
- Electrokinetic chromatography with micellar solution and open-tubular capillaryAnalytical Chemistry, 1985
- Electrokinetic separations with micellar solutions and open-tubular capillariesAnalytical Chemistry, 1984
- Nuclear magnetic resonance studies of the acid-base chemistry of amino acids and peptides. I. Microscopic ionization constants of glutathione and methylmercury-complexed glutathioneJournal of the American Chemical Society, 1973